Make Model Symptom Problem Solution By
SONY ICF200W
Open r36 When the unit is turned on after a couple of minutes a clicking noise is heard at the speaker.
SONY CDP101
Out of alignment High-frequency squeal through audio system with cdp-101 inany mode (stop/play/pause). checked completely and looked at output withoscilloscope. no high frequencies were audible.
SONY CDP101
Loose right rail on sled Loose right rail on sled. holder bracket missing.
SONY CDP101
Defective cx-79034 Static noise in both channels after 8 to 10 minutes. foundnoise being generated at output of cx-79034.
SONY CDP101
Out of alignment Rumble in audio. checked unit and found no problem. problemcould be in software or playback system. did complete alignment for unit,focus servo slightly out of range. returned to customer.
SONY CDP101
Shorted wire -10 volt line (from cn542 to cn536) was shorted to chassisnear bracket (bottom) to the rear of the sled assy.
SONY XR77
Large distortion Unit produced large distortion during tape operation withoutboard display no. 'dpl -el.
SONY TCK81
High torque measured After installing new take-up arm assembly, forward torquemeasures 55 to 65 q/cn. this may be contributing to tape skew problems,by requiring increased back tension.
SONY TCFX33
Problems around ic501 Unit will not lock into play mode and the service manualschematic does not agree with its own board layout in the book andneither agree with the board in the unit. -hq comments: release from play could be initiated by reset pulseor slow oscillator (r-c
SONY TCFX30
Grounding spring needed Intermittent static noise was recorded when humidity levelsare low, erase and r/p heads were eliminated by grounding to chassis thisproblem occurs both on record and playback. -hq comments: 1) please apply grounding spring to erase head as outlinedin ta
SONY TAN88
Open c410 The 78v line was reading about 110v on this unit and thesound was distorted. adjusting rt401 had little effect. we found c410to be open and causing the problem.
SONY TAF55
Shorted d406 The 15v line was down on this unit. we found d406 shorted(located in regulator circuit).
SONY STRVX6
Poor connections on q414 This unit had a dim display and erratic tuning q414 was found to be poorly soldered on the base and emitter leads.
SONY PSX75
Arm needed adjustment Cantilever of cartridge was being pulled to one side, bendingit eventually also mistracking in one channel, poor dynamic range, etc.
SONY ICF2001
Error in pcb diagram When rd amp fails, technician replaces q52 as labeled on pcb,diagram is incorrect.
SONY CFS10
End of tape sensor not aligned As tape moves in play mode - end of tape sensor is not alignedfully with width of tape causing uneven pressure and wrinkling of tape. -hq comments: the crease in the tape is indeed caused by excessivepressure as well as uneven placement of the pu lever
SONY AUDIO GEN
T/n #8467 T/n #8467 list ic cx807-f1 and cx807-f3 as applicable to wm-2.however wm-2 uses cx808 on first and second type board an cx887 on thirdtype board. is cx807-f1 and cx807-f3 replacement for cx808 or cx887? -hq comments: cx-807 and cx-808 ics are identical
SONY XR70
Tab adjustment needed It will not accept tape. cause: eject lever (#387) fails toengage the pin on (#385) when tape is inserted.
SONY XO5
Defective switch This unit had a bad hum in the phono mode (unless the switchwas pushed in and held in hard). the small switch (muting) along side s2would not make contact unless switch was held in.
SONY WMD6
Foil missing No ff and rewind. motor started about 2-3 seconds after theplay switch is pressed.