Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
TCM5
|
Missing parts in s/m | The mechanical layout on page 15 of the s/m is missing parts. | ||
SONY |
TCFX1010
|
Broken erase head wire | This unit had a distorted output at the p/b head(non-symetrical sine wave). this of course prevented the auto calibrationcircuit from functioning. we found a broken wire at the erase head to bethe problem. | ||
SONY |
TC530
|
Replacement motor is larger | Ic624-si motor substituted by p/n 8-832-627-00, type ic624hi. servicer states motor sub is physically larger and mounting holesare different. -hq comments: motors are direct replacement.ic624-si motor (8-832-624-09/02) = ic624-hi motor (8-832-627-00) | ||
SONY |
TC250
|
Replacement part different | X-346-011-0 is too small in diameter. the other idler part #x-027-003-0 looks more like correct diameter. -hq comments: tc-250 unit is approx. 15 years old. similar model istc-350 and tc-102. p/n for its idler is x-002-701-92 and currentlyavailable. | ||
SONY |
STRVX6
|
Defective ic503 | This unit erratically displayed two or three led segments.we found the drive ic to be defective. | ||
SONY |
STRVX6
|
Repeated inverter failure | Unit had been serviced twice before for inverter transistorfailure. first time, it was modified by moving q801 regulator transistor.second time, unit was cooked 2 weeks. before being sent back to customer,where it failed again after 3 hours of operatio | ||
SONY |
SPP11
|
Dialing pulse does not go through | Intermittently when dialing out gets a busy signal and thenumber being called rings only once and then dead line. -hq comments: although no history of such a problem, there are twothings i can think of for an incomplete call. 1) the dialing pulse width | ||
SONY |
RT66
|
Shorted d1314 | When depressing the pause switch in play mode, the unit goesinto ams mode and stops operation (head goes down), if there is a signalplayed back. | ||
SONY |
PSX600
|
Out of adjustment | 1) tonearm does not move in auto start mode, but t.t. startsturning. 2) tonearm moves manually, but sluggishly. | ||
SONY |
PSX45
|
Ic cx193 fails | This unit has repeated failure of the servo ic, cx193. alloutboard parts have been carefully checked and the unit operatescorrectly when a new ic is installed. all d.c. and waveform measurementsare within 5%. i am puzzled as to why these chips only wo | ||
SONY |
PSX6
|
Leaky d410 | After 5 minutes the repeat led would partially come on and the repeat function would not work. we found d410 in the repeat flip flop ckt leaky. | ||
SONY |
PCMF1
|
Leaky l519 and defective ic505 | Recording section worked fine but the playback section didnot function. | ||
SONY |
CDP101
|
Defective laser | Unit will not read toc (ejects after attempting to focus3 times). defective laser diode - all voltages to top correct - ld onsignal good. | ||
SONY |
CDP101
|
Defective q601 | Initially there was no system control function due todefective crystal. after replacing crystal unit worked ok for a fewminutes but shut down when jarred. traced problem to defective q601 whichshorted because of misaligned rubber insulator. i think th | ||
SONY |
CDP101
|
Sled motor locked up | Customer's complaint was stays in scan. verified problem -visual inspection showed sled motor was locked up. loosened screws onsled ass'y and motor turned freely. | ||
SONY |
CDP101
|
Out of adjustment | Dealer's complaint was won't accept disc. verified problemon bench. focus operation checked ok, unit would not read toc due to nogfs signal. | ||
SONY |
CDP101
|
Out of adjustment | Would not read toc. gfs stays low. | ||
SONY |
CDP101
|
Defective ic204 and open r390 and r391 | Unit would not function at all. | ||
SONY |
BM600
|
Defective gear | Forward will not engage because gear would slip. | ||
SONY |
XR25
|
Shorted capacitor | Not audio. |