Search: toshiba
Results: 5617
Make Model Symptom Problem Solution By
TOSHIBA 2857DB
Int. frame collapse Dry joints on regulator q420, not too easy to find as it is not close to power supply or frame stage, it is the supply to the frame generetor ic
TOSHIBA V880MS
Dead Check c822, z801, z802 cpn10
TOSHIBA 2550TB
Set stuck in standby at switch on Field output ic ta8427k faulty, also change 220uf cap
TOSHIBA 210T6BZ
Distorted sound / banging Voltage at c832 over 25v! replace q809, c866, c869, c864 and resolder dry joints in psu
TOSHIBA 145R7B
Dead D808 s/c due to high ht caused by faulty switch mode ic str50020
TOSHIBA 219T9B
Intermittent field collapse after a few hours Replace field output chip ic303 an5515
TOSHIBA 215R8N
Severe vertical distortion- `egghead` symptoms Replaced c317 in vertical cct 2.2uf, 50v substituted 4.7uf. must be 105ºtype!!
TOSHIBA 2577B
White horizontal line frame collapse Dry joint on ta8427k, frame ic
TOSHIBA 28WD98B
Stuck in standby, 16 volt line low at approx 8 volts Replaced c872 220uf, 50v, original had gone low in value
TOSHIBA 2573
Stuck in standby. Replaced zp82 o/c and tuner internal short
TOSHIBA V642UK
Vcr is locked out, no sound, noise picture and front panel buttons do not work. nvram has been lost Access the nvram menu. on remote hold a-dub button for 10secs, vcr display will read test, then hold the menu button until the nvram menu is displayed on screen. i do not know the codes for this model, if anyone knows them please pass them on!
TOSHIBA 32ZD09G C00S
Procedure to enter the service mode Press the mute key on the handset once, then press the mute key for a second time but hold it down while also pressing the menu button on the set
TOSHIBA 198X6M
Horizontal output continues to short Check capacitors c403 and c408 both 50v these two caps tend to change capacitance
TOSHIBA 2505DB
Stretched frame or frame collapse Replace modification diode 570 on copper side
TOSHIBA 175T9B
Line tearing and incorrect field lock when cold 47uf electrolytic agc decoupling capacitor inside tuner/if unit
TOSHIBA CF3060K
Problems with screen size Look out for 2 x 2.2uf electrolytics sometimes red in color
TOSHIBA 28W23B 11AK37
Picture displaced vertically, picture too high or low This problem was cured by entering the service mode menu then 4,7,2,5, then pressing the green fastext button to access geometry settings, selecting vp1 vertical position and adjusting as necessary
TOSHIBA 28W23B 11AK37
Procedure to enter the service mode Press the menu button then 4,7,2,5
TOSHIBA 2998 EMS
Blue screen, no sound and no image, with characters, no front key performs any function other than the power key Check c213 welding
TOSHIBA U16
U16
Vertical folding down Q430