Toshiba Repair Tips
Search: toshiba
Results: 5617
Results: 5617
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
TOSHIBA |
2505 , 2527
|
Dolby sound fault | See toshiba tec bulletin | ||
TOSHIBA |
2500TBT
|
Poor ew ic361 hot | D368 30v zener oc | ||
TOSHIBA |
2500TBT
|
Field scan distorted | C317 2µ2 50v | ||
TOSHIBA |
2500TB5
|
Clock stops on text holding page selected | Dry joints on xf01 on text pcb | ||
TOSHIBA |
2500TB
|
Vibration from cabinet | Refit button assy. add felt ( tape available from tec dept on request ) | ||
TOSHIBA |
2500TB
|
Severe chroma patterning from cold reduces as set | C515 22uf oc | ||
TOSHIBA |
2500TB
|
Picture visible for few secs with scan fault then | R448 2.7Ω high toshiba 4984279 ( 12v to taa8659an falls to about 8v ) | ||
TOSHIBA |
2500TB
|
Int clock stops on teletext | Resolder xtal xf01 13.875 on u101 text board | ||
TOSHIBA |
2500TB
|
If chopper tr sc check r810 330k out of cct | Ht should be set for 145v | ||
TOSHIBA |
2500TB
|
Field lin | C303 2µ2 50v in field drive near pin 32 ta8659 | ||
TOSHIBA |
2500TB
|
Field - top of pic stretched | C303 2µ2 o/c | ||
TOSHIBA |
2500TB
|
Dead int - esp when chassis slid in & out | Check resistor not touching audio o/p chip heatsink | ||
TOSHIBA |
2500TB
|
Chopper transistor sc | Check r810 330k | ||
TOSHIBA |
2500DBT
|
Poor field lin | C317 2µ2 next to fop chip heatsink | ||
TOSHIBA |
221T3B
|
Field top foldover - ok when warm. | C312 ( 10uf , 35v ) | ||
TOSHIBA |
221E
|
Frame top foldover. | C313. | ||
TOSHIBA |
21T4B
|
Frame collapse - may be intermittent. | C312 int s/c. | ||
TOSHIBA |
21S04B
|
Dead set with led blinking | Fd802 630ma fuse o/c & shorted turns loptx t444 pt no az363004 | ||
TOSHIBA |
219X9M
|
Severe foldover bottom frame low height | Replace c303 1mfd 63v | ||
TOSHIBA |
219T9B
|
Whine only | D601 s/c on 12v rail |