Search: toshiba
Results: 5617
Make Model Symptom Problem Solution By
TOSHIBA 219T9B
Ht does not get above 90v Replace c814 100mfd50v
TOSHIBA 219T9B
Dead no 5v on connector p587 pin 6 R843 15r oc
TOSHIBA 219T9B
Dead , ic801 str54041 inactive check for 5v at pin R483o/c safety resistor
TOSHIBA 219T9
Dead str54041 sc Check q802 base emitter as if sc - str will blow again .check out of cct
TOSHIBA 218D9B
No pic - blank raster when a1 advanced - sound ok No scastle pulse pin 35 ta8659n - c410 2700pf dry joint (under plastic frame by loptx)
TOSHIBA 218D9B
Field lin stretched at top C317 2µ 50v, c308 2µ2 50v - little red caps near fop chip
TOSHIBA 2173DB
Teletext off-centre Enter service mode option text and adjust
TOSHIBA 2173DB
Teletext off centre Enter service mode and select text and set up
TOSHIBA 2173DB
Set in trip R868 10k 0.5w in psu o/c
TOSHIBA 2173DB
Service mode Press mute on r/c once, then again, then press menu on tv while pressing mute on r/c
TOSHIBA 2173DB
No sound Q608, q609 in mute leaky (6342206)
TOSHIBA 2173DB
No line or field sync - heating restores Qb11 or qb12
TOSHIBA 2173DB
Int no stations, blank raster, no osd No reset pulse on pin 43 micro qa01, resolder q843 and heatsink of q840
TOSHIBA 2173DB
Dead Check r868 10k for o/c
TOSHIBA 216T9B2
Field lin C303 2µ2 50v, c317 2µ2 50v both red & possible hi esr
TOSHIBA 216T9B
Field lin probs C303 & c317 2µ2 & c313 100µ 35v o/c
TOSHIBA 216T9B
Field lin dist C303 2µ2 to pin 31 of ta8659a col dec/ tbase chip ic501
TOSHIBA 216R9B
Field collapse/lin C303 2µ2 50v
TOSHIBA 2163DB C6S
Poor character width in text mix. Q501 tb1229n poor , replace with improved type - tb1229an ptno b0102070
TOSHIBA 2163DB C6S
No line sync from cold, sound mute appears only momentarily, unable to enter service mode Cb12 560p low cap - sync pulse feed to pin 34 qa01