Search: toshiba
Results: 5603
Make Model Symptom Problem Solution By
TOSHIBA 216T9B2
Field lin C303 2µ2 50v, c317 2µ2 50v both red & possible hi esr
TOSHIBA 216T9B
Field lin probs C303 & c317 2µ2 & c313 100µ 35v o/c
TOSHIBA 216T9B
Field lin dist C303 2µ2 to pin 31 of ta8659a col dec/ tbase chip ic501
TOSHIBA 216R9B
Field collapse/lin C303 2µ2 50v
TOSHIBA 2163DB C6S
Poor character width in text mix. Q501 tb1229n poor , replace with improved type - tb1229an ptno b0102070
TOSHIBA 2163DB C6S
No line sync from cold, sound mute appears only momentarily, unable to enter service mode Cb12 560p low cap - sync pulse feed to pin 34 qa01
TOSHIBA 215T8B
Stuck in standby. Check volts at pin 7 ( 5v reset ) of micro qa01 if low check q805 if ok ica01 u/s ptno 23318387 - m34300n583sp
TOSHIBA 215T8B
No text , just page number ( which can be altered ) Cf14 0.01mfd
TOSHIBA 215T8B
Low brill/contrast , poor focus , looks like low emm Check r920 ( 3Ω ) crt heater supply
TOSHIBA 215T8B
Int. field-line collapse Dry joint scan coil connector p570
TOSHIBA 215T8B
Field foldover/cramping at top Ic340 tda2579
TOSHIBA 215R8B
No pic Int crt htrs - dry joints at p502 (under plastic loptx cover)
TOSHIBA 215R8B
Field lin C317 4µ7 50v
TOSHIBA 2151TB C4ER
Trips off after few seconds - then high Ht rose to 150v (115v) c817 22u 100v o/c
TOSHIBA 2151TB
Stuck in stby Qa10 2sc1815y or 2sc1740 leaky (reset for micro ica01 pin 43)
TOSHIBA 2151TB
Goes dead ofter 5-10 min Q831 2sc1815 leaky
TOSHIBA 2151DB
No line or field sync Ic501 tda8361
TOSHIBA 214T7B
Dead stby light goes out when remote pressed SR15.039F
TOSHIBA 214R7B
Pulses on hi brill D242 1n4148 in beam curr lim s/c
TOSHIBA 214R7B
No sound Tda1015 (ic621) audio output amp and feed resistor r830 0.56r connected to pin 4 of the chopper tx.