TOSHIBA 215T8B
Stuck in standby. Check volts at pin 7 ( 5v reset ) of micro qa01 if low check q805 if ok ica01 u/s ptno 23318387 - m34300n583sp
TOSHIBA 215T8B
No text , just page number ( which can be altered ) Cf14 0.01mfd
TOSHIBA 215T8B
Low brill/contrast , poor focus , looks like low emm Check r920 ( 3Ω ) crt heater supply
TOSHIBA 215T8B
Int. field-line collapse Dry joint scan coil connector p570
TOSHIBA 215T8B
Field foldover/cramping at top Ic340 tda2579
TOSHIBA 215R8B
No pic Int crt htrs - dry joints at p502 (under plastic loptx cover)
TOSHIBA 215R8B
Field lin C317 4µ7 50v
TOSHIBA 2151TB C4ER
Trips off after few seconds - then high Ht rose to 150v (115v) c817 22u 100v o/c
TOSHIBA 2151TB
Stuck in stby Qa10 2sc1815y or 2sc1740 leaky (reset for micro ica01 pin 43)
TOSHIBA 2151TB
Goes dead ofter 5-10 min Q831 2sc1815 leaky
TOSHIBA 2151DB
No line or field sync Ic501 tda8361
TOSHIBA 214T7B
Dead stby light goes out when remote pressed SR15.039F
TOSHIBA 214R7B
Pulses on hi brill D242 1n4148 in beam curr lim s/c
TOSHIBA 214R7B
No sound Tda1015 (ic621) audio output amp and feed resistor r830 0.56r connected to pin 4 of the chopper tx.
TOSHIBA 214R7B
Int reverts to st/by Dry joints pri joints st/by tfmr
TOSHIBA 2145DB 2545DB
Changes in contrast when playing back dvd with macrovision Add 47k resistor between pins 54 & 61 ta88088n ic501
TOSHIBA 2145DB
Dead with ht at 50v but comes up to 150v after disconnecting line o/p Replace d474
TOSHIBA 2141RB
Dead - st/by only R878 27r o/c
TOSHIBA 2140RB
Field collapse No 8v supply pin 10 ic501 tda8361- c503 220µ 16v s/c & r480 4r7 1/2w fusible o/c
TOSHIBA 213T4B
Slow start up C814 22mfd 50v in psu