Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
XR44
|
Radio intermittently shuts off by itself | This unit was intermittently shutting off by itself in theradio function. the solder was not sticking to the diode lead. it wasas though the lead was not clean or had a cold solder connection. thelead would slip right through the solder connection. h | ||
SONY |
ESR10
|
Radio shuts off by itself | This diode has a cold solder connection or a dirty lead andthe solder will not stick to the lead. | ||
SONY |
D7S
|
Unit will not play | No focus search. this problem may have been caused byservicer after he replaced fop. l504 was open and there was a soldershort under it which was causing pins 18 and 20 of ic502 to be shortedtogether. | ||
SONY |
RME100V
|
Use of editor with jvc hr-7650u vhs vcr | Vcr has 10 pin camera jack. do we make an adapter to inter-face with rme-100v? -hq comments: we currently have no adaptors available for vhs vcryou may however suggest to the customer to contact a video supply outletwhich carries adaptors. the adaptor | ||
SONY |
SLHF1000
|
Tearing at top and bottom of pix in bi slow and still | Tearing at top and bottom of pix in beta i, slow and stillmode. all other speeds look ok. tape path also checked good. ialso seen sl-hf750 -hq comments: we have evaluated this unit. a combination of tape path,bi rf switching adj., and slow tracking | ||
SONY |
KV2780R
|
High pitched squeal (audible) all the time, replace yoke | Audible high-pitched squeal from inside tv cabinet all thetime. we are beginning to see numerous complaints of high-pitchedsqueal from 27 tv receivers. | ||
SONY |
KV2093R
|
Picture bounce, replace if block | After about 15 min. picture would bounce and with the audioreceiving both sap and main there was a pop in the right channel. videoin was good. found this to be heat related as cooling if block unit wouldgo back to normal. | ||
SONY |
KV25XBR
|
Vertical jitter on pay-per-view channel | Customer in chicago subscribing to group w cable set experi-ences vertical jitter and roll on pay-per-view channel only. all otherbroadcast and pay channels ok. -hq comments: pls compare composite video waveform at pin 22/ic1501 forok channels and the | ||
SONY |
CDP620ES
|
Will not read toc - noisy focus search | Unit seemed to have a focus servo or search problem. withscope on fo test point, focus search going up was ok but in focus searchgoing down there seemed to be an open servo loop. | ||
SONY |
CCDM8U
|
Need part number for chassis on page 126 | Need part number for chassis on page 126. -hq comments: the part number is a-7010-080-a. a s/b will be issued. | ||
SONY |
TCFX510R
|
Incorrect description in s/m | Correct p/n for case, silver should be 3-307-532-31 and forblack one should be 3-307-532-11. -hq comments: we will issue a service bulletin. | ||
SONY |
SDP505ES
|
Wrong part number | Ic702 (cxp5016h-118s p/n 8-759-800-54) was ordered from kcp.received p/n 8-759-800-54 (an la3365 ic). la3365 is correct. micro-processor has incorrect part number. | ||
SONY |
FD3A
|
Dial pointer, x-3332-204-1 | Pointer missing from unit. pointer is not declared onexploded views in fd-3a or fd-2a manuals. | ||
SONY |
KV2080R
|
Pop in sound, value changes | With external amplifier/speaker pop in sound when changingchannels. -hq comments: to fix the problem make the following component changes:c1461, c1462 from 1u/50v to 4.7u/50v (p/n 1-124-192-00)r1461, r1464 from 22kΩ to 1kΩ/1/6w (p/n 1-247-831-00). | ||
SONY |
CDXR7
|
Pll free run frequency adjustment | To adjust pll free run - l501. | ||
SONY |
STRAV580
|
No memory | No memory of stations. | ||
SONY |
EVS700U
|
Intermittent noise during pcm playback (tracks 4, 5, 6) | 1) pcm playback of tracks 4, 5, 6 has dropout during audioplayback. 2) stereo indicator light flashes. 3) video playback has noiseat bottom of screen. | ||
SONY |
STRVX350
|
No audio output | The speaker relay would not engage although the audio outputsand sensing circuits were ok. | ||
SONY |
CCDM8U
|
Drum rotation is erratic and unit shuts down | Drum is erratic and unit shuts down. -hq comments: check c246, md-10 board. we have reports on this capbeing leaky. please inform results. | ||
SONY |
CCDV3
|
No eject | No eject. unit had been dropped and case was damaged. |