Mitsubishi Repair Tips
Search: mitsubishi
Results: 1346
Results: 1346
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
MITSUBISHI |
TC 2009
|
Oscillates and goes into `standby` protection | D552 shorted, possible vertical shorted too. There's no point in loosening it, you have to change it | Gutierre | |
MITSUBISHI |
2099
|
Does not turn on blinking LED, low power supplys | Primary capacitors | Replace c-905,906,907 | WARLEY CESAR |
MITSUBISHI |
TC2010
|
Vertically closed, touch the plate to open it, but the light streak is tortuous, suggesting that it was the deflector coil | Poor contact in the connection socket with the vertical deflection coil. | It was resoldered and it was ok | Armando de Olimpia Eletronica EvoluSom. |
MITSUBISHI |
TC-2098
|
Power supply arms and disarms | 07. | Replace. | Edigar de Souza Moulaz |
MITSUBISHI |
TC-2009
|
Diagonal lines over the image, on all channels, also on av. | C-206 | Replace it | Ronan Nolasco |
MITSUBISHI |
TC 2099
|
Image with little brightness | R 559 open (connects the 170v to the acl"abl") | ||
MITSUBISHI |
TC 2010
|
Ic 901ice1qs01 ic 951 tl 431 | sidney valentina | ||
MITSUBISHI |
TC 2099
|
Interference on the image as if it were a lack of general synchronism, in rf or av. | C 705 (1mf/50v),replace s/ medir. | Esper | |
MITSUBISHI |
14 NãO TEM O MEDELO
|
No contrast and little color | R559 220k | Replace | EletroClaudio Aguas Belas |
MITSUBISHI |
TC-2099
|
LED flashing, power supply does not stabilize | R908 open near c907 | Resolved by replacing the 10k r908 | PATRICK |
MITSUBISHI |
TC-2010
|
This TV had all voltages on the secondary power supply, ok, but it did not generate high voltages. | Q551(2482) open, and c573 altered in horizontal amplification. | Swapping the two solves the problem. | Eletrônica Barros(Léo) |
MITSUBISHI |
TC-2098
|
With charged capacitor | 47k open r904 | R904 - de 47k | |
MITSUBISHI |
TV2098
|
I'm ruim | Capacitor c305 open | orlando lott | |
MITSUBISHI |
TC 2041S
|
Has difficulty calling, sometimes calls, sometimes doesn't call | R 916-150k open. change.,it may be open or altered. | Perse | |
MITSUBISHI |
TC2090
|
Does not pick up low channels | Probable cause c7 t1- o.01uf- shorted. ceramic capacitor. | Perse | |
MITSUBISHI |
1419
|
Password locked channels | With the TV in stand-by, press on the TV panel, volume + and - simultaneously, wait until it turns on, then go to the menu using the remote control and deactivate the "lock" function, then turn it off and on again. If necessary, repeat the procedure more than once. If you can't, change the memory. | Software reprogramming | Osmar Antonio |
MITSUBISHI |
TV1410
|
Power supply keeps oscillating at 48v when turning off the tr.horizontal output voltage remains normal | Shorted deflector coil or internal leak | Replace the original deflector coil. at1625 | ELETRO CENTER |
MITSUBISHI |
TC-2098
|
Without horizontal synchronization, does not tune channels | Cap. c208,1uf x50 v | pardalzito | |
MITSUBISHI |
TC-2099
|
Doesn't tune in, and doesn't come in | R744 of 8k2 micro pin 41, may be open | Bruske | |
MITSUBISHI |
TC -1409
|
Does not turn on, power supply keeps trying to arm, LED blinks. | C-954 /r954 | Replace the capacitor (runaway) and the open resistor. | WARLEY CESAR |