Philco Repair Tips
Search: philco
Results: 4775
Results: 4775
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
PHILCO |
TP20V56
CP02R0 |
Doesn't start | D909 in the power supply secondary | luiz g.silva | |
PHILCO |
TP20V56
CP02R0 |
Doesn't start | Power supply secondary d900 | luiz g.silva | |
PHILCO |
PCM2044
|
Verticalopen only 5cm from the middle upwards | C-613 pin 3 of vert output. 2n2 was with 1n6 | joaoxx | |
PHILCO |
TP-2052N
|
Does not turn on, LED off, device inoperative without voltage on the power supply secondary. | Cold welding at the power supply. | Resolder r910, r909, d906 and points on the same power supply line. | celinvds |
PHILCO |
TP1410
|
Standby is on but when I turn it on it starts blinking but doesn't oscillate the TV only has +b 106 volts | 15 homs resistor burnt or with raw solder check it position r931 and it feeds the 1000mf x 16 volt capacitor take advantage and change it without testing the c918 | ||
PHILCO |
TFP2902
|
Horizontal shifted right side | Capacitor c732 smd 2n2 | ||
PHILCO |
PCM 2044
05 |
Vertical closed dark strip at the bottom | Capacitor 1000uf35v no esquema c610 | I replaced it, it was a jewel | dgspeg |
PHILCO |
PCM2044
05 |
Vertical closed dark strip at the bottom | Capacitor 1000uf35v | I replaced it, it was a jewel | dgspeg |
PHILCO |
PCS-2956
CPO1LR01 |
TV with no image and no sound; with line of retraces. | Irregularities in the ic101 (m37274ma), memory, blocked the system when activating the image adjustment in the menu. | After replacing the ic 101 (m37274ma), the device was ok. | clayton |
TV PHILCO |
PCM 2044
|
Blinking led | Takes about 20 minutes to work | Solution capacitor c722 470μFx25v, replaced and resolved. | BF.COLATINO |
TV PHILCO |
20V56
|
With drizzle. | None of the channels worked, before condemning the seletronic I checked that it had 33v and the appropriate voltages, but when checking the date and clock line I saw that tsound was no clock signal. | Following the seletronic backwards I saw that r202 100r smd version was open. because tsound was a sign on one side and not on the other. I replaced it and that's it. all channels are working again | BF.COLATINO |
TV PHILCO |
PCM-2046
|
Doesn't start | After finding that the c716, r706 were broken and replaced | I checked that the flayback was shorted and I replaced the components and everything went back to normal. | BF.COLATINO |
TV PHILCO |
2956 N
|
Entering protection resolved | The problem with the TV was the wide capacitor (c 728-3u3 1k6) | Replaced and resolved. | BF.COLATINO |
PHILCO |
PCM 2044
|
Turns on and off without stopping | R115 open and c718 shorted. | These two components are part of the 180v power supply. | BF.COLATINO |
PHILCO |
PCS-2976S
|
Reduced frame on the sides, stretched vertical, strange characters and could not access service mode. | 24c04 smd memory | Memory replacement | Evandro Bobsin cardoso |
PHILCO |
TP2054
|
Image playing beautiful and off | I thought it was flye bek, but it was the 6n8 715 capacitor, I just had to change it | jcosme | |
PHILCO |
TP2053
21 |
Stop had no main power supply | Ic 901 q 901 tda16846 short, just change it, it works, it works fine | negodrama | |
PHILCO |
TP20V56
|
Inoperative, tsound is only voltage on the primary power supply | Change power supply oscillator ci tda16846 p ic901 | ||
PHILCO |
PT1410
|
Turning off and flashing stand by | Change 1000/16v supply capacitor | ||
PHILCO |
TC-29A11
|