Search: samsung
Results: 3847
Make Model Symptom Problem Solution By
SAMSUNG CI5061
Pic shifted to right C404 2n7 & check r420 820k
SAMSUNG CI5052XT P68
No s/v , with sby light flickering Sdh209b ic801
SAMSUNG CI5052XT
St/by only C852 470µ, c418 1µ 250v hi esr, q402 2sd 1651 (loptr) s/c, r826 1r ½w o/c- replace loptr with correct type (i didn't & it went s/c again 3 days later!)
SAMSUNG CI5052XT
No sound/vis with st/by led flickering 125v ht only 70v; ic801 sdh209b
SAMSUNG CI5052XT
Hum bar C851 100µ 400v mains smoother o/c
SAMSUNG CI5052X
St/by only 86v ht, r813 o/c
SAMSUNG CI5052X
Int low brightness A1 pot on loptx & c907 10nf 2kv
SAMSUNG CI5052X
High ht should be 125v C852 470µ 16v
SAMSUNG CI5052AT
Height reduces with bounce Ic402 12v reg mc7812
SAMSUNG CI5052AT
Frame collapse Check d412 and r412
SAMSUNG CI5052AT
Field lowers when warm then bounces Ic402 mc7812
SAMSUNG CI5052 P68
"store" & "channel" in flash on screen 1n4148 diodes in key strobe lines to micro ric01 leaky
SAMSUNG CI5052
No sigs & partial field collapse B+ (12v) to tuner low at 1.4v. r419 10r safety res o/c (not shown in manual)
SAMSUNG CI5038Z
Tripping with ht low at 102v instead of 125v Smr earthing was suspect on heatsink (new type device recently fitted) i psu
SAMSUNG CI5030AN
Slightly off tune at sw on gradually improving C401
SAMSUNG CI5030AN
No pic for up to an hour No line lock - adj h sync preset
SAMSUNG CI5030
No sound. X601 xtal ( stereo sound
SAMSUNG CI5027
Dead 4 x bridge rects, str50103, d801 r2ky caused by faulty scan coils
SAMSUNG CI501FT5X
Bright white raster at sw on then trips out & repeats Zd201 5v1 zener faulty - line pulse clamp pin 42 tda8842 jungle chip
SAMSUNG CI5013T P58SC
Wont start or trips , with no sby light Checkr 811 100k