Sony Repair Tips
Search: sony
Results: 20090
Results: 20090
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CDX5090
|
Error code e44 | Servicer has unit that customer complained it dropped out oncein awhile. servicer has not been able to duplice problem. put unit intest mode. after 6 hours of playing e44 came up on display but unit kepton playing. noted fpr 03252. here's another er | ||
SONY |
CDX5090
|
Discs would load but not play (removed foreign material) | The discs would load but would not play. | ||
SONY |
CDX5090
|
Faceplate will not stay on (lever on lock assy was broken) | The faceplate would not stay secured to the main unit. | ||
SONY |
CDX5090
|
No display illumination (replaced lamps pl801 and pl802) | There was no illumination for the display. | ||
SONY |
CDX5090
|
Amp remote line does not activate (reslodered cnp501 pin 3) | The unit would not output any voltage on the amp remote leadwhen the unit was operating. | ||
SONY |
CDX5090
|
Display failures (missing segments, cracked lcd, etc.) | Various display failures have been noted, such as missingsegments, cracked lcd, segments always illuminated, etc. | ||
SONY |
CDX5090
|
Skips (found optics bad; rf level less than .9v p-p) | Unit skips. | ||
SONY |
CDX5090
|
Broken buttons/keyswitches | - button stuck down, + button broken. | ||
SONY |
CDX5090
|
Suts off when in cd modes (found optic bad) | Shuts off when in cd mode. at times, unit skips sittingstill. | ||
SONY |
CDX5090
|
Skips, even when vehicle is stationary (found optic bad) | Skips, even when the vhicle is not moving. | ||
SONY |
CDX5090
|
Kss313a optics in place of kss410a | Some cdx5090's have kss313a optical in them, even though themanual indicates kss410a optical. | ||
SONY |
CDX5070
|
Unexplained error code in test mode: "e-a0" | An unexplained error code appeared on the display while in thetest mode. the code is e-a0. -hq comments: tokyo told us that program bugs may account forunexplained error codes. in this particular case, the e-a0 appears whenthe unit tried to eject the | ||
SONY |
CDX5070
|
Error code e44 | Servicer has unit that customer complained it dropped out oncein awhile. servicer has not been able to duplice problem. put unit intest mode. after 6 hours of playing e44 came up on display but unit kepton playing. noted fpr 03252. here's another er | ||
SONY |
CDX5060
|
Unexplained error code in test mode: "e-a0" | An unexplained error code appeared on the display while in thetest mode. the code is e-a0. -hq comments: tokyo told us that program bugs may account forunexplained error codes. in this particular case, the e-a0 appears whenthe unit tried to eject the | ||
SONY |
CDX5060
|
Error code e44 | Servicer has unit that customer complained it dropped out oncein awhile. servicer has not been able to duplice problem. put unit intest mode. after 6 hours of playing e44 came up on display but unit kepton playing. noted fpr 03252. here's another er | ||
SONY |
CDX45RF
|
Skips when playing outer tracks (see bulletin 358r2 for fix) | The unit skips when playing the outer (higher number) trackson the disc. | ||
SONY |
CDX45RF
|
Skips (cleaned excess grease frok mechanism) | Skips on outer tracks of disc. | ||
SONY |
CDX45
|
Skips when playing outer tracks (see bulletin 358r2 for fix) | The unit skips when playing the outer (higher number) trackson the disc. | ||
SONY |
CDX4090
|
Continually blows fuses (found d599 shorted) | The unit was dead and continually blew fuses. | ||
SONY |
CDX4090
|
Won't load discs (found spring ref. 103 out of position) | The unit would not load discs. |