Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
CCDTRV30
|
No audio/ reconnect cn302 au185 | No audio at all | ||
SONY |
CCDTR80
|
Battery end adjustment data address is incorrect in s/m | When setting up to read data for battery end adjustment,value at address 47 does not change per procedure on page 7-62 of servicemanual. | ||
SONY |
CCDTR5
|
No rec on camera/caution mode in ff- replace cassette holder | Camera section cannot rec on vtr section, when you ff theunit will go into caution mode, found cassette holder bad. | ||
SONY |
CCDTR5
|
Dark pix in camera/no character display in vf/cn802-vc60 | Unit has dark pix in e-e on camera section and no charactersyn. found cn802 on vc60 loose. | ||
SONY |
CCDTR400
|
Battery end adjustment data address is incorrect in s/m | When setting up to read data for battery end adjustment,value at address 47 does not change per procedure on page 7-62 of servicemanual. | ||
SONY |
CCDTR101
|
No function power ok- ic924/vc103 | Unit was tampered with by other service dealer. unit did notfunction, no camera or vtr. found ic924 mode control ic bad the ic onlyinitialized reset, no power on vtr/camera on line. | ||
SONY |
CCDTR101
|
Intermittent poor eject/ m902 | When power is restored on vtr/camera, found mechanism problemon emergency mode. i can load and eject tapte but sometimes on eject, itejects out 2/3 then stops found capstan not turning. -solution :replace a used capstan m902, restored unit to normal. | ||
SONY |
CCDFX630
|
Rainbow color distortion/ic505 vs110bd resolder | Rainbow color distortion when recording over old recordings(fe head is not working) found problem to be intermittent whendisassembled, pressed on vs110 board, found problem to be cold solderedic505. (fe on command int.) | ||
SONY |
CCDFX630
|
No record/ #117 switch block control | Unit would not record, everything else ok. resoldered ic505,a couple of times, still no rec. i noticed using a remote, unit wouldhave vtr functions when in cam mode, this lead me to vtr/cam sw. | ||
SONY |
CCDFX530
|
No evf/shutdown problem/ ic501-vf44 | No video in viewfinder, camera will the shutdown. appears tobe a syscon problem, but camera will work fine when viewfinder isdisconnected. the 5 volt line to evf is loaded down when connected. | ||
SONY |
CCDFX510
|
Intermittent color/ x301- va-74bd | Received a few reports of intermittent color. problemoften goes away if case or board are slightly stressed. problem causedby intermittent color crystal, x301 on va74 board. when in failure modefrequency of operation is around 5 mhz. replacing re | ||
SONY |
CCDFX510
|
No color in playback/ic301-va74 pin 14 resolder | No color in playback. | ||
SONY |
CCDFX435
|
Dead unit/x301 vs110 bd | Unit dead except for ever 5v. mode cpu/ic503 dead in water. caused by defective x501/32khx clock which must run for the cpu to wake upand activate the master clocek. replacement resolved problem. | ||
SONY |
CCDFX420
|
Bw pix in rec everything else ok/c019-cs37 bd | Cn505 pin 11 to c019 the other side goes to pin 2 of ic001rfc line. fouind c019 missing. | ||
SONY |
GDM20SE1
|
H pin/key bal, centering, and d focus off | Unable to adjust horiz. pincushion and keystone balance.horiz. centering and dynamic focus were wrong. | ||
SONY |
GDM20SE1
|
Picture offset right 2 inches | Picture was moved to right 2 inches in all modes. normalvga mode had enough range to set back to center, but mode 5 and above didnot have enough range. | ||
SONY |
CPD1425
|
H. position control vr defective | Picture shifts horizontally. | ||
SONY |
CDU33A
|
No audio windows 95 | Customer had no audio. audio line from headphone jack wasok. video data to computer was ok. | ||
SONY |
WMFX415
|
No audio from tape (radio o.k.) - replace head cable | Either no audio from tape, or audio only from one channel. | ||
SONY |
WMFS495
|
Defective headphones | Headphone ear piece broken. may have been shipping damage orjust hard use. |