SONY ITA3000
Defective keypad - resolder connector cn101 Keypad will not register #, 0 or * out to the phone line.found an open between cn101/pin 29 and cn102. resoldering cn101 fixesthis problem.
SONY ITA2500
Vox dtmf test - replace ic504, p/n 8-759-996-43 No telephone line signal detection on dtmf display. there wasa signal coming in ic302/pin 11 to ic504/pin 2(input). there was no signalon ic504/pin 1 (output). ic504 was defective.
SONY ITA2500
Defective ram test - reseat connector cn102 No response when pressing keyboard dial buttons. i cleanedkeyboard and resoldered ic701. still the same problem. i found cn102connector was cold soldered.
SONY ITA2500
Defective bell detect - remove solder splash at mj301 No ring and no connect, seized a line. q301 checked o.k.i found mj301 jack had a solder splash underneath the connector, pinsshorted together.
SONY ITA2500
Defective bell detect - replace q301, p/n 8-729-927-24 No ring and its connect or seized a line. i checked q301 andemitter shorted.
SONY ITA2500
Icm timing failure - replace c539, p/n 1-163-809-11 Calling in for incoming message, took only 10 seconds max. isuspected problem in the vox detect chip ic506. no signal was going intoic506/pin 1 output, but ouput ic504/pin 1 signal was getting thru, ifound c539 capacitor chip broken.
SONY ITA2500
Ogm line distorted - remove solder bridge at ic301 Distorted audio at on hook and handset dial tone. i hadtraced the problem into ic301, but the ic is working correctly. i hadvisually inspected and found ic301/pin 8 and 7 shorted together.
SONY ITA2500
Defective bell detect - replace lf301 Unit will not ring/connect. checked ring signal and foundlf301 to measure open. fuse f301 checked out ok.
SONY MDP605
Unit locks up at stop, will not eject disc After pressing stop from normal ld play, disc drawer would notopen for several minutes. found that, although braking was applied to discmotor, there was insufficient coupling between disc and turntable assy,allowing disc to spin free of the decelerating
SONY MDP600
Disc rotation stops Disc rotation stops.
SONY TCWR820A
Will not record on left channel of a & b deck Only right channel is being recorded. lpf 101 (filter, lowpass) defective. pin 1, 2, 3, on the ic501 has a lot of signal but pin 4has not signal. causing left channel with no audio recorded.
SONY TCFX211
Distorted audio - replaced t/u reel Distorted audio sound when playback after record. problem usually happens at the end of the tape.
SONY TAE2000ESD
Wrong ic designation number in manual Ic672 (center channel amp) is printed in all sections ofmanual as ic762.
SONY TAAV521
Capacators vented electrolyte over pcb - replaced capacitors Caps blew and vented all their electrolyte causing minimaldamage to the pcb. also, noted that the original capacitors were rated at63v instead of 71v. the replacement part number is 112573011 which is71v.
SONY STRD790
Muting light always on - replaced q211 Q211 defective, muting lighting up all the time.
SONY STRD590
Surround in/op, when it works its very loud - repl ic304 Rear channel has loud volume, with no ajustment. i found ic304defective.
SONY STRD590
No rear output - replaced q602, relay drive transistor Unit received w/complaint of no rear output.
SONY STRD315
Shorted output transistors on nbo Output transistors short causing no audio. two units, sofar. serial # for other unit is 8803448. these transistors are on nbo. -hq comments: checking with kc parts, there are currently about 200pcs on nbo. at this time, eta is listed for arrival in mi
SONY STRAV970X
Distorted audio - replaced ic701 Unit had slight distortion on rt channel. bias was wrong.signal at the base of ouputs appeared clipped. checked input signal.it appeared normal and equal on both channels. voltages on rt side ofic701 revealed problem.
SONY STRAV970
No tuning & no eq graphics - replaced ic973 No tuning and no eq display graphic.