Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
HCDC55
|
How to replace the optical block | Need assistance how to replace the optical block, reallyeasy. not to spend more time to disassemble the whole tranport and set. -hq comments: there is a fair amount of disassembly required to accessthe optical block in this unit. we have faxed tokyo req | ||
SONY |
HCDC50U
|
Need extension cable to align cd - see s/b hfp #407 | It is very difficult to align the cd mech. in this unit.there needs to be an extension cable or jig to hold the cd section foralignment. -hq comments: we will fax tokyo and inform them about this situation.a s/b has been issued (hfp #407) with a new ex | ||
SONY |
HCD541
|
Need part # for reel cap | Reel cap is shown in manual as not supplied. we need thepart #. | ||
SONY |
DXAH2750
|
Fan run constantly - replaced ic910 | Fan runs constantly. | ||
SONY |
DXAH2750
|
Power on is inoperative for several seconds after turn-off | Operator complained that unit would not turn on again, untilseveral (up to 10) seconds after turn-off. if he pushed the power buttonimmediately after turn-off nothing would happen. | ||
SONY |
DXAC70
|
Will not turn on - replaced defective ic821 | The standby light is on but unit will not turn on. found pin8 of ic901 at 0 volts. this needs to be +6.8v. by opening traces andmonitoring the volume found the on/off switch of ic821 pin 28 notfunctioning. checked all required for processor, all ok. | ||
SONY |
DTC700
|
Loading problem - replaced mech control ic312 | Unit was not loading the tape and tape compartment was openingagain out after it closed. it was acting like the end loading switch was | ||
SONY |
DTC59ES
|
Can't find tracks on ams - re-aligned mech, adj back tension | When doing forward or reverse search unit will loose count andstop. | ||
SONY |
DTC59ES
|
Unit goes into caution -refer to fpr#p1417 | After (rw) rewind, unit goes into caution. when in the stopposition if you press play, nothing happens. if you hit the open/closebutton twice the unit will function. you can also reset the systemcontrol by unplugging the unit to return to normal opera | ||
SONY |
CDPX222E
|
Goes into shuffle mode at power up - replaced ic401 | Unit goes into shuffle mode when at turn on and no play. | ||
SONY |
CDPC705
|
Intermittant shuffle - re-greased disc tray washer | Shuffle function will forget disc (the disc willintermmitantly not align properly with bu bracket and display will read nodisc) | ||
SONY |
CDPC322M
|
Disk tray closes after 3 seconds - open trace on near s702 | The unit intermittently closes disk tray after 3 seconds. | ||
SONY |
CDPC322
|
Jerky tray, open close movement - lubricated mechanism | Jerky tray motion at open, or close command. | ||
SONY |
CDPC235
|
After warm up, display blinks and stop playing | After unit warmed up, display blinks and stop playing duringtrack change and look for another disc. after intensive trouble shooting,we found a defective diode in positive 9.5v supply. if 9.5v supply dropsto below 6.8v, unit will reset. we think, diode is | ||
SONY |
CDPC235
|
Table keeps rotating with less than 3 discs | With less than 3 discs in unit the table will continue torotate unless you put some pressure on the turntable to slow it down.with 3 discs it will detect the discs and play them. with 1-2 discs itwill not detect the discs and play unless you put slight | ||
SONY |
CDP411
|
Duplicate service bulletin numbers | Service bulletin # 397 for hi-fi products (csa-13) has beenassigned twice: may 27, 1994 - cfd-560 extension cable part number, and june 24, 1994 - cdp-411 no disc appears during play. -hq comments: this error had been picked up by the publication | ||
SONY |
CDP311
|
Distorted audio - replaced l292 | After unit starts up in play mode, audio starts to distortuntil there is only static. | ||
SONY |
GENERAL
|
Leader laser meter probe - use "lpm8001 sensor" when ordering | The probe for laser meter defective, price for completereplacement probe is $266.00. | ||
SONY |
BM246
|
Will act erratic with auto change on, replace nd901 display | When auto change is on and in record mode, there will be anerratic operation of both decks. the record mode may stay on deck a anddeck b will go into rewind by itself. also, both displays will displaycas/err/# sector will give different values. when t | ||
SONY |
XRU880
|
Pop in audio when buttons pressed | Audio popped each time a button was pressed on the faceplate that activates the mute transistors such as seek +/-, mau. +/-.scoping the outputs on dc range showed a dc offset ranging from 100mv toas much as 900mv. pop occured because mute transistors tak |