Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
DXAC70
|
No output - ic703 defective | Found output from ic was high causing unit to go intoprotect. | ||
SONY |
DTCM100
|
Display malfunction - replaced defective d901 | Display reacts to level meter and some portions of display arelit dim that should not be on at all. | ||
SONY |
CDPX777ES
|
Drawer jam when closed or will not close - align brkt & plte | When you closed the door, it closes all the way, than itsnaps closed with a jolt. when you try to open drawer you must push itand once again there is a jolt, then door opens. | ||
SONY |
CDPH3750
|
Jamming discs | Disc comes off tray and jams mechanism. this problem happenson all 5 disc drawer changers. we already put messages about rough edgesand thick disc within the units but we still have repeat repairs on thisproblem. as we are judged on customer returns, | ||
SONY |
CDPH3750
|
Drawer will not stay closed - q304 and d327 dusty | When you attempt to close a drawer the drawer closest to the center position and reopens. | ||
SONY |
CDPH3750
|
Intermittent drawer will not open - cleaned s101 | Intermittently in shuffle, unit would stop playing disc anddrawers would not respond to open command or load discs. load discsdisplay no disc and drawers would not open. | ||
SONY |
CDPH1750
|
Intermittent drawer will not open - cleaned s101 | Intermittent in shuffle unit would stop playing, disc anddrawers would not respond to open command or load discs. displays no discand drawers would not open. | ||
SONY |
CDPC89ES
|
Intermittent disc skip, tray always rotates - rollers flat | The unit is continuously spinning the tray or intermittentdisc skip. troubleshooting, i found that the rollers for the tray wereworn flat. the flat rollers prevent the mech. control from identifyingthe disc location. | ||
SONY |
CDPC89ES
|
Mechanical noise during open/close/disc skip - adj bracket | When units press open/close or disc skips it would make aclick click mechanical noise. as soon as i took the cover off, i saw thatthe bracket (press pulley) was set too low. when the tray turned, thebracket and tray contacted each other. | ||
SONY |
CDPC500
|
Constant sled motor movement - resoldered cn1001 | Sled motor continues to try to move sled in, switch closed.disc tray may not open. | ||
SONY |
CDPC435
|
Unit had power but was inoperative - cn801 makng bad contact | Unit had power but was inoperative. | ||
SONY |
CDPC345
|
No part # for front foot - p/n is x49445291 | There is no part number for the front foot of the cdpc345.part x49435101 is (cdpc235) the front panel assy which appears to comewith the front foot. if we order x49435101 we get the front panel for thecdpc235. there is not part # for the front panel of | ||
SONY |
CDPC245
|
Disc table rotates slowly - replaced rotary gear | Disc table rotates slowly. | ||
SONY |
CDPC245
|
Missing part - installed missing tension spring | Lock lever will not engage (stay put), tension spring wasnever installed in unit. | ||
SONY |
CDPC235
|
Static in audio out - replaced ic501 | Static in audio, traced signal to ic501 sound was good goinginto the ic but bad going out. | ||
SONY |
CDPC201
|
Disc table does not open - replaced ic401 restored operation | Disc table does not come out. disc chucks five time and stops.when i pressed disc skip or disc table open, unit did not respond. -soulution: found the main cam gear had a dent in the rim. i replacedit, but this did not solve the problem. i then replaced | ||
SONY |
CDP270
|
No operation, no display - replaced ic12 | The unit was not completely dead, but had no display or buttonoperation. | ||
SONY |
AVU270
|
No rear channel - resoldered pcb | Found ring crack on rear output. | ||
SONY |
XRU880
|
Reference number correction (ref. 36 and ref. 37) | Ref. #37 in exploded view is listed with part number for rcajack and vice versa for ref #36. so when you order ref. #37 you will getref #36 part which could get confusing. | ||
SONY |
XRU800
|
No functions (replaced ref. #7; spring (sw)) | Unit did not work. checked unit and found the sw spring onsub panel was bent, and could not push nose switch s510. |