Make Model Symptom Problem Solution By
SONY HVA441
D601, d602, d603, d604 wrong part number listed. Part number listed as: 8-719-906-39 is wrong. should be8-719-300-33.
SONY CCDVX3
Top of picture distorted unit vibrates/replace drum Picture was distorted. replaced drum. problem became worse.replaced supply reel and back tension band. still a problem. took notethat unit had a vibration in play.
SONY CCDVX3
Zoom stuck - open unit, npf/ see sb csv-3 #335 I have several units 34, 17534, 08, 17826, 44, 59856, and now12, 47526. the flex cable gets dimples in it from cr 42 board c046 andarea. the flex cable is nbo and the customers tend to get irate. 12,47526 says rush on it.
SONY CCDVX3
Unable to perform back flange adj. Technician attempted to perform the back flange adjustment.tried several times but unit would lock up before completing adjustment.
SONY CCDV99
Speed changes from sp to lp during scan (c837) Refer to fpr o3609. although replacing c833 effects a cure,additionaly replacing c837 further reduces the noise and enhances the longterm performance of this unit.
SONY CCDV5000
Poor video in forward search (tearing): ref 304 left coaster Unit had excessive hitches in forward play, forward search hadan unusable picture.
SONY CCDV101
Int or no audio/c562 leaks onto feed opens clock to au60 Int or no audio, checked data lines into au60 pcb. found nosck. followed trace back and was open (int). found leaky cap c562 overfeed through.
SONY CCDTR91
Premature tape end detection/resolder connectors on sl32 5 min tape end comes on too soon intermittent. is there a similar fix like sb cam-0333 for the fx310? please call 612-920-3655 ext 319. -hq comments: please resolder all connectors on the sl-32 board. thisusually corrects this problem.
SONY CCDTR91
No color in vf during record/resolder x601 This camera would show no color in the viewfinder pictureduring record. it would, though, during playback. this was caused by apoor solder connection at x601 on the vc board. although the crystal wasoperating it was pulled slightly off frequency by the r
SONY CCDTR91
Glass on ccd imager cracked Horizontal line across picture in evf and playback. i foundthat glass on ccd imager cracked in a half and it created line acrosspicture. so far, i have seen two of this type problem.
SONY CCDTR91
Black & white viewfinder video/replace x601 There was no color in the viewfinder e-e only. playback wasok. found that x601 was drifting.
SONY CCDTR91
Ic501 change Ic501 875284249, description cxp80624a-025r is used. thispart is not listed in kc system and cannot be ordered.
SONY CCDTR91
No autofocus or zoom/replace ic655 No autofocus or zoom.
SONY CCDTR91
Unit will not go into record while in standby/check cn451 Unit is powered up and there is camera video but it will notswitch to record. -resolder cn451 on dd55 bd.
SONY CCDTR808E
Black bars on left side of screen/change c353 to 6.8uf Faint black noise bars appear on the left side of screen.they are approximately 1/2/to 3/4 inch wide. this occurs only on its ownrecording. nothing can be seen e e. prerecorded tapes no problem. thisis noticed more in bright scenes.
SONY CCDTR71
Missing part # for capstan connector Part # for capstan connector missing from sm. cn502 isnot part of fp-182 (w403) 1-630-591-11.
SONY CCDTR700
Tape pre-end signal always on/check cn873 Tape pre-end signal always on.
SONY CCDTR7
Viewfinder picture dark/change c301 Unit came in with fiewfinder picture darker than normal. e-ewas fine. after swapping out the entire vf, i measured the video signalat pin 3 of cn951 which measured lower than normal. going to q230, idiscovered the base was reading .9v and the emitter
SONY CCDTR61
Horizontal jitter, ee, after warmup/replace ic704 After warm up, pix would jitter horizontally at about a 1hzrate. this would show up in ee and also be recorded on tape.
SONY CCDTR500
Won't load or unload The loading motor gear breaks loose from the drive shaft.