SONY LBTD1110
No audio deck a & b - connector(s) disconnected Many units have been sent to repair for no audio in decks a &b. one of the units connecting wires is becoming disconnected atconnector: cn1211, cn1212, cn410 or cn411, causing no audio output. thereis no apparent cause for these disconnections, and a ma
SONY HSTH1750
Part number for sys con 2 cable What is the part number of the 17 pin flat cable thatconnects the hsth 1750 to the cdph1750? this is part of the mhc1750system. -hq comments: the p/n for the cable is 1-696-412-11.
SONY HST231
Weak right channel - replaced defective switch, ic203 Right channel is weak.
SONY HCDC50U
Cd scrapes - add screw to base plate Ref fp03504 - cd will make scraping sound when playing. wehave performed the following solution on over 20 of these units with nocustomer returns.
SONY HCDC50U
Intermittent sound - resoldered ic951 Intermittent no sound.
SONY HCDC50U
Cd jams inside the unit - slider pin ref 365 out of position This complaint usually takes the form of will not play mycds or there is a cd caught inside. it is not in the system buttechnicians are seeing the problem more than once. referring to pg.106 ofthe service manual item 365, slider pin, jumps out of its pos
SONY GEN-HFP
Availability of surround tester (part number t-9985-569-1) It is difficult to troubleshoot the surround processingcircuitry of receivers.
SONY CDPC910
Bent chassis prohibits reliable repair On several units we have had the bottom of the md section withmajor bends. we have tried to straighten these with little success. itwould take a rebuild to replace the chassis parts. are there any options? -hq comments: the problem with the sample we
SONY CDPC735
Power unit on, only pause light on - replaced ic801 Powering the unit on, found only light on front panel waspause.
SONY CDPC535
Disc tray (table) spins constantly - replaced rotary gear Disc tray runs slowly causing micro to not be able to readphoto sensors properly.
SONY CDPC435
Wiring harness to rotary encoder not seated properly Player exhibited symptoms similar to either flex cable orcontrol problems. door opening and closing by itself, b.u. assembly wouldgo up or down or do nothing. it did not know where it was.
SONY CDPC335
Noise on loud passages - ic501 defective Crackling during loud sound passages. more apparent usingtrack two of yeds-18. input pins of ic clear of distortion. at the outputpins, the signal was clipped and oscillating. -hq comments: ic501 is the line amp/muting att.
SONY CDPC335
Bu unit hits disc table when chucking On 2 different units the laser hits the disc table whenchucking. it appears disc table, ref# 59, is stopping too far clockwise.the pin on ref# 123 is against the left side of the slot in ref# 59. isthere any adjustment? what makes the table stop in th
SONY CDPC322M
Intermittent cd - replaced ribbon cable from bd to main brd Cd would operate intermittently.
SONY CDPC235
Bu unit hits disc table when chucking On 2 different units the laser hits the disc table whenchucking. it appears disc table, ref# 59, is stopping too far clockwise.the pin on ref# 123 is against the left side of the slot in ref# 59. isthere any adjustment? what makes the table stop in th
SONY CDP211
Won't read toc - defective 0ptics, ic-291 and x301 Unit would not read toc or play. traced problem to meltedobjective lens cover. also had defective ic291 and x301.
SONY GEN-HFP
Replacement disc for cd skipping checker - p/n j2501066a I would like to know the part number for the cd drop outchecker test disc? -hq comments: the p/n for the replacement disc is j-2501-066-a.
SONY XRU660
Loses presets, clock resets to 1:00 (replace reset ic101) The unit's presets are lost, and the clock resets to 1:00.
SONY XRU550
Loses presets, clock resets to 1:00 (replace reset ic101) The unit's presets are lost, and the clock resets to 1:00.
SONY XRU330
Loses presets, clock resets to 1:00 (replace reset ic101) The unit's presets are lost, and the clock resets to 1:00.