SONY CDPC425
Noise in audio (replace ic301, p/n 8-752-337-26) Digital noise heard in audio out. another servicer hadreplaced ic302 and ic303 before sending in to us. i have had other unitsthat have had similar problems w/audio noise such as static or no audioat all.
SONY CDPC325
Noise in audio (replace ic301, p/n 8-752-337-26) Digital noise heard in audio out. another servicer hadreplaced ic302 and ic303 before sending in to us. i have had other unitsthat have had similar problems w/audio noise such as static or no audioat all.
SONY CDPC225
Noise in audio (replace ic301, p/n 8-752-337-26) Digital noise heard in audio out. another servicer hadreplaced ic302 and ic303 before sending in to us. i have had other unitsthat have had similar problems w/audio noise such as static or no audioat all.
SONY CDPC625
Noise in audio (replace ic301, p/n 8-752-337-26) Digital noise heard in audio out. another servicer hadreplaced ic302 and ic303 before sending in to us. i have had other unitsthat have had similar problems w/audio noise such as static or no audioat all.
SONY KV32XBR95S
Schematic diagram of crt pin allocations are incorrect The schematic diagram of the crt pin allocations, on page114, are incorrectly labeled. the c board lay out is correct. -hq comments: please refer to the schematic diagram located in theservice manual of the kv-27xbr96s for the correct pin allocationsch
SONY KV27XBR95S
Schematic diagram of crt pin allocations are incorrect The schematic diagram of the crt pin allocations, on page114, are incorrectly labeled. the c board lay out is correct. -hq comments: please refer to the schematic diagram located in theservice manual of the kv-27xbr96s for the correct pin allocation
SONY KV32XBR90S
Schematic diagram of crt pin allocations are incorrect The schematic diagram of the crt pin allocations areincorrectly labeled. the c board lay out is correct. -hq comments: please refer to the schematic diagram located in theservice manual of the kv-27xbr96s for the correct pin allocationschematic. a ser
SONY KV32TS46
D612 p/n and description correction D-612 on page 112 is listed as d5sc4mr p/n 8-719-031-80 this is incorrect. -hq comments: the correct description and part number is listed below: d612 d5sc4m 8-719-031-79
SONY KV32TS36
D612 p/n and description correction D-612 on page 112 is listed as d5sc4mr p/n 8-719-031-80 this is incorrect. -hq comments: the correct description and part number is listed below: d612 d5sc4m 8-719-031-79
SONY KV27TS36
D612 p/n and description correction D-612 on page 112 is listed as d5sc4mr p/n 8-719-031-80 this is incorrect. -hq comments: the correct description and part number is listed below: d612 d5sc4m 8-719-031-79
SONY KV27TS29
D612 p/n and description correction D-612 on page 112 is listed as d5sc4mr p/n 8-719-031-80 this is incorrect. -hq comments: the correct description and part number is listed below: d612 d5sc4m 8-719-031-79
SONY WMGX90
Intermittent record - resolder record switches Intermittently would not record.
SONY DD8
Dark lcd display, not adj via user controls/rv701 open Dark lcd display not adjustable to a good viewable intensitywith contrast control.
SONY KV32XBR96S
Intermittent caption character error, change r3443 value Intermittly the caption character will turn into a white orblack box. -hq comments: this symptom depends on the video siginal level.changing the resistance value of r3443 from 470Ω to 100Ω willcure the problem. p/n 1-216-025-00 100Ω 1/10w
SONY KV27XBR96S
Intermittent caption character error, change r3443 value Intermittently the caption character will turn into a whiteor black box. -hq comments: this symptom depends on video siginal level.changing the resistance value of r3443 from 470Ω to 100Ω willcure the problem. p/n 1-216-025-00 100Ω 1/10w
SONY CCDF301
Data transfer from computer to camera stalls on address 6 When using the lanc jig to transfer data from the computer tothe camera, the program would fail with a communications error whenever itgot to address 6. this is a read-only location for the battery downvoltage adjustment.
SONY CCDV701
Spurious dew sensor/remove lithium battery - reinstall Had a continuous dew indication. replaced dew sensor with nochange.
SONY PSFL99
Arm drops too fast - tighten lifter assy ref. #217 Tonearm drops onto record without any damping.
SONY XRU880
Replacement keyswitch different from original Replaced switch with one from diagnostic board. -hq comments: this problem was also reported on the xr-u770. npcchecked with tokyo and found that the part number in the manual iscorrect, but that the switch vendor supplied the wrong switches. npc hasp
SONY CCDTR101
Possible poor bass response at high sound levels Customer was taping marching band with ccd-tr101 camcorder andnoticed poor bass response compared to other camcorders.