Sony Repair Tips
Search: sony
Results: 20100
Results: 20100
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
PSFL99
|
Arm drops too fast - tighten lifter assy ref. #217 | Tonearm drops onto record without any damping. | ||
SONY |
XRU880
|
Replacement keyswitch different from original | Replaced switch with one from diagnostic board. -hq comments: this problem was also reported on the xr-u770. npcchecked with tokyo and found that the part number in the manual iscorrect, but that the switch vendor supplied the wrong switches. npc hasp | ||
SONY |
CCDTR101
|
Possible poor bass response at high sound levels | Customer was taping marching band with ccd-tr101 camcorder andnoticed poor bass response compared to other camcorders. | ||
SONY |
SPPA60
|
Icm cuts off early - replace ic3, p/n 8-759-089-98 | When incoming message time set to 4 min., rec will cut off atabout 10-15 sec. when set to 1 min, it works ok. | ||
SONY |
XRU110
|
Incompatibility between cdx-a30/xru110/xa-18 | Cdxa30 does not work with xru-110 & xa-18. when you firstturn on power, all cd functions work fine. but, when i press reset buttoncd does not work. i have to turn power off and on again to get systemworking again. | ||
SONY |
CCDTR55E
|
Washed out picture in camera mode/check c-304 vc60 | Unit came in with stuck iris. after restoring iris function,the unit displayed washed out picture with poor chroma and poor contrast.found c304 missing. the board looked like it was never soldered or a verypoor soldering job. | ||
SONY |
CFD440
|
Wrong power cord | Part #1-557-287-11 for cfd-440 power cord, as listed inservice manual, is for a non-polarized detachable cord. a polarizeddetachable cord is actually used. #1-558-834-11 seems to work. it ispolarized on both ends and detachable. -hq comments: please | ||
SONY |
ICFM200
|
No power or intermittent power - replace ic4, p/n 875993761 | The unit had no power at all. after removing back of unit,the unit would work when the main board was tapped. i followed thevoltage to ic4 and found that ic4 had 5.1v going in and 0v coming out.after replacing ic4, i had 2.7v out, but still no power. | ||
SONY |
FD230
|
Horizontal line across screen (vert. collapse), c-502 | Television had audio but with a horizontal line across thescreen. no visible cracks or bad solder connections. found signal atic501/pin 2 to be noisy and containing ripple. found c502 open. | ||
SONY |
CFD757
|
Schematic error | Schematic error for the cfd-757. the unit actually conformsto the schematic for the cfd-758. the error in on page 63. it involvesr358 and r365. -hq comments: tokyo has been informed and will issue a s/m supplement ora correction manual in mid-december | ||
SONY |
TAAX301
|
Part number change on transformers t1, t2 - see correction-2 | The part numbers for the power transformers t1 and t2 on thismodel have been changed. | ||
SONY |
TCWR635S
|
Circuit change on main board - see s/m supplement-1 | The main board (p/n 1-647-190-11) has been changed (new p/n1-647-190-13). | ||
SONY |
CDX5460
|
Explanation of error codes not shown in service manual | Is there a list of the error codes available for the abovemodel? how about other models? -hq comments: the list of error codes for this model is limited, andunfortunately the explanations are not very descriptive. the only errorcodes we know about ar | ||
SONY |
CDX5060
|
Explanation of error codes not shown in service manual | Is there a list of the error codes available for the abovemodel? how about other models? -hq comments: the list of error codes for this model is limited, andunfortunately the explanations are not very descriptive. the only errorcodes we know about ar | ||
SONY |
TCC5
|
Method for cleaning tcc5 pinch rollers | Tcc5 pinch rollers can't be cleaned without disassemblingcassette tray and front panel. | ||
SONY |
CCDFX310
|
No ee video/replace timing generator ic 801 | Unit had no ee video. | ||
SONY |
KV27V55
|
Buzzing, applied silicon to t601 - ac line filter | Buzzing in the set, no matter if the set is on/off. | ||
SONY |
XRU770
|
No operation; reset only (replace d511, p/n 8-719-977-07) | When power was applied to unit, reset was noted but, no otheroperation was possible. since i was already familar with the zener diodeson data and clock lines that either leak or are shorted, i checked d513and d514. these were ok. on this model there | ||
SONY |
CCDV5000
|
No video | No ee or pb video. using the ccdv5000 troubleshooting guide,we traced the signal up to pin 16 of the hd8 hic board, but a very weakone coming out of pin 20. | ||
SONY |
SLV585HF
|