Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
D4
|
Irregular speed - bad spindle motors, p/n x-2641-521-1. | Many reports of bad motors. irregular speed causes ticking inaudio. if you hold motor and spin, you will feel the irregularities. -hq comments: your samples have been sent to tokyo for evaluation. wehave already sent samples to tokyo in january 1993. | ||
SONY |
ITD250
|
Handset mutes when extension phone is picked up | Handset mutes when extension phone is picked up. this iscaused by line loading. the 12v off-hook line voltage of this unit getsloaded down to less than 6 volts when an extension phone is picked up.this unit will stop working at a line voltage less than | ||
SONY |
ITD200
|
Handset mutes when extension phone is picked up | Handset mutes when extension phone is picked up. this iscaused by line loading. the 12v off-hook line voltage of this unit getsloaded down to less than 6 volts when an extension phone is picked up.this unit will stop working at a line voltage less than | ||
SONY |
ITD150
|
Handset mutes when extension phone is picked up | Handset mutes when extension phone is picked up. this iscaused by line loading. the 12v off-hook line voltage of this unit getsloaded down to less than 6 volts when an extension phone is picked up.this unit will stop working at a line voltage less than | ||
SONY |
CFD30
|
Plastic cd holder breaks | Plastic cd holder breaks at screw lobe near spindle motor. isuspect that the cause is there is too much weight for 1 screw lobe tohold. i suggest modifying the cd holder, reference 103 by adding ribbedsupports on the spindle motor end of the holder. -hq | ||
SONY |
KV32TW75
|
No video/audio, hv ok, removed solder bridge on c1266 | The unit would turn on, but would not have any video or audio, high voltage was present. | ||
SONY |
ICFSW55
|
M3 will not program- also cannot erase memory presets | The memory position m3 will not program properly, also itcannot erase memory positions. | ||
SONY |
SLV585HF
|
Mechanical noise in cue/rev/ff/rew: pully 309 x37277821 | A mechanical noise during cue/review and ff/rewind sounds asthough the capstan motor is dragging. | ||
SONY |
SLV595HF
|
No drum or capstan motor rotation: q211 ma106 | No drum, or capstan motor rotation. | ||
SONY |
SPP170
|
Siezes line, but no dial tone on handset (151) - change q-7 | No dial tone, or intermittent dial tone on handset. the unitseizes the line ok though. | ||
SONY |
SLV585HF
|
Intermittent vcr jog/shuffle control: clean cn804 mf122 bd | Intermittently, when using jog shuffle to rewind, the unitwill go into fast forward instead. | ||
SONY |
CCDFX410
|
Pin descriptions for w500 (fp425) sl22 bd/use fx420 s/m | Schmetic shows part # 164211812 for sl-22 board. board inunit has 164211816, and has 26 pins on w500 (fp425) instead of 24as shown in manual (see page 141). is there a supplement? -hq comments: at this time, there is no supplement for the servicemanu | ||
SONY |
TCDD7
|
Unit does not appear to enter the auto power-off mode | The customer complains that the unit does not enter theauto power-off mode, even after the unit has been in stop for more than 10minutes. -hq comments: in reality, the unit is entering the auto power-off modeafter being in stop for 10 minutes, (display | ||
SONY |
CCDFX510
|
No color in playback, camera video okay/leaky c310, va-74 | No playback chroma. the camera video was okay when monitoredat video out. | ||
SONY |
KV1380R
|
Vertical roll, replace c230 | I received a unit from an authorized servicer with a verticalroll. he already tried a new jungle ic with no change. after verifyingthe problem, i fed video into video input and found that it workednormally. looking at the v sync pulse and comparing vi | ||
SONY |
KPR53EX35
|
Line in screen, external pencil mark | Customer complained of a line going through his picture. | ||
SONY |
MDPK5
|
No remote operation: l801 on sb-701 board | No remote operation. | ||
SONY |
MDP510
|
Chatter when tray moves: clean & lube loading gear shaft | When the tray is operated in and out, there is an extremelyloud chattering and vibration. | ||
SONY |
CDXA55
|
Disc unloading incomplete, magazine won't eject | The cd returned to the correct slot, but not completely intothe slot. this was caused by slider #115 not moving. found stud of thedr gear (ref. #112) broken. | ||
SONY |
XVT33
|
Background is magenta, not white/resolder c-327 | The background on the crt is magenta due to the loss of g-ysignal at the input of ic304 on the en-5 board. |