Make Model Symptom Problem Solution By
SONY HCDH1700
No display - open c922 on power supply board 1-124-478-11 The unit did not have any display. it was missing +33 volt dcline to display.
SONY HCDD117
No audio any mode - q1121 faulty, p/n 8-729-900-36 The unit had audio into the function ic ic1002 but no audioout. i found pin 6 always high (+5). from the chart below on page 15,this indicated a video switch went to the microprocessor. function a,function b, and function c lines were proper for tape
SONY TCWR570
Deck "a" will not play - s86 improperly configured The a deck would not go into play after the unit was powereddown. if tape was ejected or switch pcb cable was removed and triedplay, the unit would then function. i replaced the micro ic801 and halfswitch s86 but that did not correct the problem.
SONY STRGX99ES
Noise when changing volume - ic514, 8-759-801-01 On the center channel, as we increased the volume, the audiooutput was extremely noisy. it sounded like a dirty volume control. ireplaced the volume control but it had the same problem. i found cleanaudio into pin 2 ic514. pin 1 on ic514 had noisy au
SONY SPP90
Intermittent change in tx frequency - replace c-549 When twisting the handset main pcb i noticed that the transmitfrequency would jump from 49.845mhz to 49.850mhz. this was true for bothchannels (a 5khz difference in frequency). after taking voltagemeasurements around q508 and q509, i could not come up w
SONY TAAX390
Noise in audio from volume control motor - ic901 875963261 When the volume control is operated from the remote, themotor noise is heard in the speaker. changing the motor had no effect.
SONY MDP605
No disc rotation-mech noise: center-guide 305 and spring 304 The center guide holding clasps broke, causing the guide andspring to fall into the mechanism.
SONY CDX4040
Slow eject cycle (replace sw80, sw81, p/n 1-571-754-11) The tuner operation was normal. when ejecting the cd, the mechanism will move to the lock position, but the solenoid plunger 332 will take thirty to forty seconds to engage to finish the eject cycle.
SONY KV19TS20
Auto program does not work, adjust agc When you push the auto program button, the unit goes throughchannel but: unit #1 programs all channels in and stops on 72. unit #2programs some channels in, but none of the active channels. activechannels are 2, 4, 6, and 12 and this set programs in 5
SONY D36
Intermittent operation - cracked main board The unit has intermittent operation. i found a crack in theboard just left of the line out jack (component side). i have seen thison more than ten units and several had to have boards replaced. none ofthe units had any sign of physical damage. screw
SONY CFS905
Unit drains batteries - c-354 leaky (p/n 1-161-379-00) The unit drains batteries when in tape mode and tape is notbeing used, with the unit off.
SONY SLV750HF
Intermittent loss of video from tuner: open trace at q803 Intermittently, the video would flash on and off. i tracedthe video from the tuner and found an open trace between r811 (q803,emitter) and r838.
SONY CDX4040
Distorted cd audio, tuner ok (replace flex cable ref. 322) The unit was distorted when playing a cd. ic3 pin 78 signalslooked slightly distorted.
SONY KV27TS36
Telematic adapters, see tv service bulletin # 158r1 What adapters do we use on this model?
SONY KV27TS32
Telematic adapters, see tv service bulletin # 158r1 What adapters do we use on this model?
SONY D101
The unit will not operate on battery power - dc jack open The unit will not operate on battery power- dry cell andrechargeable batteries. the negative battery terminal does not groundbecause the switch in the dc power jack is open. this switch grounds thenegative battery terminal.
SONY STRAV1070X
Hiss in center channel on dolby mode I have two units where the customers have complained of a hissnoise on the center channel output. most of the complaints are about therear channel. no information is available on this, please give advice assoon as possible.
SONY CDXU8000
Does not play cd's (replace "b" flex board p/n 1-634-333-11) The unit will not play cd's. i found the flex connectorcracked where the shield comes in contact with it, this also applies tosn 103563 and 107614.
SONY CDX5260
No response to minus button, replace sw818, pn 1-572-704-21 The minus select button of the unit is inoperative. theswitch is not physically worn out since it still clicks when pressed, butit will not make contact electrically.
SONY CCDTR31
Service manual errors Page 126 (av-138 board) shows 3.6 vdc at pin 2 of ic602 andpage 108 (vs-95 board) shows 0.5 vdc at pin 13 of ic407. which is thecorrect signal? -hq comments: correct voltages are as follows: ic602 pin 2: 0 volts dc ic40