Search: sony
Results: 20100
Make Model Symptom Problem Solution By
SONY SLV555UC
Lost of contrast in loop through When the playback output signal of another unit is loopedthrough the slv-555uc, the picture looses contrast.
SONY XR7300
Missing part number, knob (handle fitting) The lift tab on the handle (knob, handle fitting) does notcome with the new handle and most service manuals do not have the partnumber listed.
SONY XR5507
Missing part number, knob (handle fitting) The lift tab on the handle (knob, handle fitting) does notcome with the new handle and most service manuals do not have the partnumber listed.
SONY XR4057
Missing part number, knob (handle fitting) The lift tab on the handle (knob, handle fitting) does notcome with the new handle and most service manuals do not have the partnumber listed.
SONY UP850N
Printer is noisy when using upp-110hd paper When upp-110hd paper is used, the unit squeaks and makes loudnoises like old typewriter striking the roller. when you use the upp-110spaper, everything is quiet. the only difference between the paper is theupp-110hd has a shiney surface. we are going
SONY CCDTR4
Capstan error Using the rm-95 and looking at last fault it showed 00:04(capstan error). mr. takesue informed me he has seen 3 or 4 with thisproblem and it turns out to be the flex connectors (pins 1 and 2). itseems that the pins are pushed down where their not makin
SONY SLV575UC
Capstan motor stops in ep After about 10 to 15 minutes, the capstan motor stops thenstarts up and then stops again. found the motor getting hot and motorshorting.
SONY HST69
Replacement ic causes distortion in output After replacing the power amp si-1125hd (p/n 8-759-301-25)with its perscribed replacement, the new ic produced noise on the output.tried another replacement and problem remained. also removed thecapacitors as described in hi-fi bulletin no. hfp0116 to n
SONY XR5500
Missing part number, knob (handle fitting) The lift tab on the handle (knob, handle fitting) does notcome with the new handle and most service manuals do not have the partnumber listed.
SONY KV27EXR15
Dark picture, replace q-711 on "c" board Unit had very low luminance chroma present and predominatelyred. looked very much like a low screen voltage problem. troubleshootingthe c board showed 200v on r, g and b output collectors. they werenot turned on. found q-711 base at .22v and emitter
SONY XM3520
Protection turns on The protection circuit is activated when the unit is connectedto other equipment or when it is tested.serial numbers applicable: up to 30,750.
SONY MDP200
No clv lock on cd - ld ok Cd would not lock, no play but ld is ok. authorized servicerreplaced cd spindle motor. i looked in the computer - sdis and read fprnumber l1639. it said magnet was too weak for cd. i didn't believe thatchanging the magnet would solve the problem but
SONY HST201
Both tape decks aren't working - capstan pushed back Everytime customer put a cassette into the unit the capstanwas pushed back because the plastic washer cannot hold the capstan inplace.
SONY KV32XBR75
Int. picture shrinking,troubleshooting tip for power supply I have had several xbr sets with complaints of intermittentpicture shrinking. solution was no regulation of the b+ which was lower-ing under load. here is a simple procedure that can be used when trouble-shooting this type of failure: operate the set w
SONY KV32XBR55
Int. picture shrinking/troubleshooting tip for power supply I have had several xbr sets with complaints of intermittentpicture shrinking. solution was no regulation of the b+ which was lower-ing under load. here is a simple procedure that can be used when trouble-shooting this type of failure: operate the set w
SONY KV32XBR65
Int. pic shrinking/trouble shooting tip for power supply I have had several xbr sets with complaints of intermittentpicture shrinking. the solution was no regualtion of the b+ which waslowering under load. here is a simple procedure that can be used whentrouble shooting this type of failure: operate the set wi
SONY KV32XBR50
Int. pic shrinking/trouble shooting tip for power supply I have had several xbr sets with complaints of intermittentpicture shrinking. the solution was no regualtion of the b+ which waslowering under load. here is a simple procedure that can be used whentrouble shooting this type of failure: operate the set wi
SONY KV32XBR10
Int. pic shrinking, trouble shooting tip for power supply I have had several xbr sets with complaints of intermittentpicture shrinking. the solution was no regualtion of the b+ which waslowering under load. here is a simple procedure that can be used whentrouble shooting this type of failure: operate the set wi
SONY KV32HSR10
Int. pic shrinking/trouble shooting tip for power supply I have had several xbr sets with complaints of intermittentpicture shrinking. the solution was no regualtion of the b+ which waslowering under load. here is a simple procedure that can be used whentrouble shooting this type of failure: operate the set wi
SONY KV27XBR65
Int. pic shrinking, trouble shooting tip for power supply I have had several xbr sets with complaints of intermittentpicture shrinking. the solution was no regualtion of the b+ which waslowering under load. here is a simple procedure that can be used whentrouble shooting this type of failure: operate the set wi