Make Model Symptom Problem Solution By
SONY KV27XBR15
No picture sleep light on, replaced c-500 ("a" board) Sleep light is on, has no picture. found .7vpp on pin 31 ofic-301 (should be 2 volts). found shorted c-500. -hq comments: when c-500 (on pin 1 of ic-500) shorts, vertical drivesignal will be lost. with the loss of output signal on ic-500/pin 3causes th
SONY KV27XBR10
No picture sleep light on, replaced c-500 Set has high voltage. sleep light is on, but set has nopicture. found .7vpp on pin 31 of ic-301 (should be 2 volts). replacedshorted c-500. -hq comments: when c-500 (on ic-500/pin 1) shorts, vertical drive signalwill be lost. with no output signal o
SONY KV32HSR10
No picture sleep light on, replaced shorted c-500, no v Set has high voltage. sleep light is on, but set has nopicture. found .7vpp on pin 31 of ic-301 (should be 2 volts). replacedic-500 and ic-301 still not working properly. found shorted c-500. -hq comments: when c-500 (on pin 1 of ic-500) shorts, ver
SONY KV27EXR15
No picture sleep light on, replace c-500 Set has high voltage. sleep light is on, but set has nopicture. found .7vpp on pin 31 of ic-301 (should be 2 volts). replacedic-500 and ic-301 still not working properly. found shorted c-500. -hq comments: when c-500 (on pin 1 of ic-500) shorts, ver
SONY KV27EXR10
No picture sleep light on, replace c-500 Set has high voltage. sleep light is on, but set has nopicture. found .7vpp on pin 31 of ic-301 (should be 2 volts). replacedic-500 and ic-301 still not working properly. found shorted c-500. -hq comments: when c-500 (on pin 1 of ic-500) shorts, ver
SONY KV20EXR10
No picture sleep light on, replaced c-500 Set has high voltage. sleep light is on, but set has nopicture. found .7vpp on pin 31 of ic-301 (should be 2 volts). replacedic-500 and ic-301 still not working properly. found shorted c-500. -hq comments: when c-500 (on pin 1 of ic-500) shorts, ver
SONY KV32XBR65
Pincushion distortion, cold solder joint d-512 No horizontal pincushion correction occurring. as received,set had overheated and open l-501, open r-571 and shorted q-505. afterreplacing these, set would work normally for about 30 seconds. q-505would short, r-571 would open sometimes l-501 would op
SONY KV32XBR50
Pincushion distortion, coldered solder joint d-512 No horizontal pincushion correction occurring. as received,set had overheated and open l-501, open r-571 and shorted q-505. afterreplacing these, set would work normally for about 30 seconds. q-505would short, r-571 would open sometimes l-501 would op
SONY KV32XBR15
Pincushion distortion, replaced r571,l501,d512 cold soldered No horizontal pincushion correction occurring. as received,set had overheated and open l-501, open r-571 and shorted q-505. afterreplacing these, set would work normally for about 30 seconds. q-505would short, r-571 would open sometimes l-501 would op
SONY KV27HSR10
Pincushion distortion, cold solder joint at damper circuit No horizontal pincushion correction occurring. as received,set had overheated and open l-501, open r-571 and shorted q-505. afterreplacing these, set would work normally for about 30 seconds. q-505would short, r-571 would open sometimes l-501 would op
SONY KV27XBR50
Pincushion distortion, cold solder joint d-512 No horizontal pincushion correction occurring. as received,set had overheated and open l-501, open r-571 and shorted q-505. afterreplacing these, set would work normally for about 30 seconds. q-505would short, r-571 would open sometimes l-501 would op
SONY XR7180
Erratic tape functions and display, no audio No display, no am, no fm tape runs but just auto-reverses.
SONY MDP210
Correction to service manual, rf pll freerun adjustment On page 130 of the mdp-210 service manual, item 7-9-3, itlists the measurement point as ic-003 pin 70. ic-003 is an 8-pin chip.
SONY SEQ555ES
Will not power up Unit doesn't power up. relay wouldn't close and there was noillumination on front panel. standby supply working. limited activity onkey matrix. seemed micros were not communicating properly.
SONY SLV575UC
White streaks - drop outs The playback picture was full of white streaks and drop-outs.the problem was caused by the static brush on the top of the drum. weused a little emery and a drop of lubricant to resolve the problem. thereis no number in the service manual for this part.
SONY CDPC5F
Faulty play This unit would only play disc in no. one position. it wouldrecognize all discs, but when called to play another it always goes backto position one.
SONY CCDF36
Does not rewind with 120 minute tapes Would rewind 60 min. tapes but not 120 min. tapes. determinedthat slower rotation of reel tables with 120 min. tape let reel fg pulsesgo too low.
SONY CDXR79
No functions, all lcd segments illluminated constantly Unit sent to dallas ssc from authorized servicer who wasunable to cure a disc loading problem. when checked by dallas technician,the unit was inoperative except for lcd segments being lit constantly. ifthe deck is disconnected from the unit all other f
SONY CDPC705
Turntable continually rotates The turntable continually rotated. all front panel controlswere inoperative. we found the problem to be a poor connection at ic-302/pin 42. resoldering resolved the problem.
SONY SLV676UC
Threading guide cracked The left plastic molded threading guide has a crack in it.this causes erratic/no threading. since the threading guide is moldedonto the metal chassis, it is necessary to replace the chassis assembly.this is the fourth report i have received regarding th