Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
KV27XBR50
|
Loud high pitched noise from set, replaced t-602 | Loud, high pitched noise from set and is not in audio circuit.sounds similar to yoke with singing problem. before replacing yoke pleaseread. | ||
SONY |
KV27XBR15
|
Loud high pitched noise from set, replaced t-602 | Loud, high pitched noise from set not from the audio circuit. | ||
SONY |
CCDV9
|
Characters are displayed e to e mode | Characters that are normal displayed on the evf are also dis-played on the monitor. refered to ccd-v9 troubleshooting guide for titlecircuit description. traced problem to ic-001, no output (cg wind) on pin32. input ref. signal (v ref.) at 2.5 volts p | ||
SONY |
LCHM30
|
Part number for the screws and nuts | If the rivits come loose on the hinges or buckles, pleasereplace the rivits with screws, washers and nuts listed below: - screw(+) m3*10 2-388-258-01 - washer m3 7-688-003-12 - nut n3 type 2 7-684-023-04 | ||
SONY |
LCHM20
|
Part numbers for screws and nuts | Part numbers are now registered for the screws and nuts onthe hinges and buckles of the lch-m20 and are as follows: - screw(+) m3*10 2-388-258-01 - washer m3 7-688-003-12 - nut n3 type 2 7-684-023-04 | ||
SONY |
KPR46CX50
|
Child picture appears detune/color fades, replaced if block | While viewing child picture, it would appear to detune andcolor would fade out. we found bad connection on t1 in the if blockassembly. soldering the connections resolved the problem. i cannot lo-cate this part description or part number in the service | ||
SONY |
KV32CX10
|
Set would lose cable channels, replace s-1316 "m-1" board | Set would lose cable channels intermittently. found cableswitch contact intermittent. | ||
SONY |
ITD250
|
Error in the service manual | The frequency of oscillation of the crystal x1 is listed inthe service manual as 300 khz. however, the reading on the crystal is800 khz. -hq comments: the service manual is in error. the correct frequency is800 khz. thanks for the info. | ||
SONY |
ITD150
|
Error in the service manual | The frequency of oscillation of the crystal x1 is listed as300 khz in the service manual. however, the reading on the crystal is 800khz. -hq comments: the correct frequency is 800 khz. the manual is in error.thanks for the info. | ||
SONY |
KV32XBR65
|
Horizontal rgb lines in top portion of picture, r-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. normally, adjusting the reffunction in the service mode will shift the lines out of the picture area.however, in this case the shift was not enough. | ||
SONY |
KV32XBR50
|
Hor. rgb lines in top portion of picture, replaced r-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. normally, adjusting the reffunction in the service mode will shift the lines out of the picture area.however, in this case the shift was not enough. | ||
SONY |
KV32XBR15
|
Horizontal rgb lines in top portion of pix, replaced r-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. normally, adjusting the reffunction in the service mode will shift the lines out of the picture area.however, in this case the shift was not enough. | ||
SONY |
KV32XBR10
|
Horizontal rgb lines on top of picture, replaced r-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. normally, adjusting the reffunction in the service mode will shift the lines out of the picture area.however, in this case the shift was not enough. | ||
SONY |
KV27XBR65
|
Horizontal rgb lines in top portion of pix, see sb # 76 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. normally, adjusting the reffunction in the service mode will shift the lines out of the picture area.however, in this case the shift was not enough. | ||
SONY |
KV27XBR60
|
Horizontal rgb lines in top portion of picture, see sb # 76 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. normally, adjusting the reffunction in the service mode will shift the lines out of the picture area.however, in this case the shift was not enough. | ||
SONY |
KV27XBR50
|
Hor. rgb lines in top portion of picture, replaced r-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. normally, adjusting the reffunction in the service mode will shift the lines out of the picture area.however, in this case the shift was not enough. | ||
SONY |
KV27XBR15
|
Hor. rgb lines in top portion of picture, replaced r-517 | Unit looks normal but, displays red, green and blue horizontallines on the top portion of the picture. normally, adjusting the reffunction in the service mode will shift the lines out of the picture area.however, in this case the shift was not enough. | ||
SONY |
CCDF45
|
No video | Ic-202 had input but no output. pin 14 0v, pin 12-15-18, 4.5vwhich is high. | ||
SONY |
TAAX401
|
Intermittent loss of audio/unit appears dead | Customer complaint of no power. on bench unit workednormally until main pcb was flexed slightly. when flexed, audio on bothchannels would go out and the front panel appeared as if unit was off. | ||
SONY |
CCDTR5
|
No y out of camera (only color) | Customer complains picture is a negative in viewfinder.found it has no y. |