Make Model Symptom Problem Solution By
SONY KV19TS20
No color, replace ic-303 No color. color hue, brightness, sharpness adjustments causeddisplay bar to change but no change in picture. no change in outputs ofic-303. data bus present.
SONY WMF2061
Incorrect part number for tape head Part number shown on page 14 of service manual, ref. hp-901,is not correct for the head in this model. the part number listed is fora motor. -hq comments: the correct part number for the head is 1-543-705-11.thank you for bringing this error to our att
SONY MDP510
Will not play discs Spindle motor will not turn focus error in on ps-193 ok.
SONY KV27XBR10
Picture blanks on in-active stations, replaced d-303 Picture would blank if you tuned to an in-active station.
SONY KV27XBR15
Shutdown with crt connected With crt connected set would shut down. with crt disconnectedset would operate.
SONY KV32XBR15
Audio balance was completely to the right, replaced ic-102 When set turned on, audio balance always was completely to the right. reset balance and set was ok until power was turned off. the balance was always to right on turn on.
SONY ITK500
Radio audio on speakerphone When you press the speakerphone, the radio audio wound bleeding.
SONY ITA600
Icm tapes being eaten and audio fluctuation on playback Icm message tapes were being eaten and curled up on the top 1/4 of the tape. when it did play, the audio fluctuated.
SONY SPP80
No microphone audio from base when using speakerphone Intermittent microphone audio output could be heard in handsetfrom base when using speakerphone by flexing pcb or hitting unit lightlyon top, but audio would soon be lost.
SONY ITA850
Intermittent icm will not operate - sometimes ogm won't Reel sensor won't count intermittently, thus shutting down icmtape mostly but also sometimes the ogm. problem is during manufacturing.bracket (part no. 112) somehow was made that when ic pcb no. 906 fits intono. 112, there is space for movement between
SONY ITA750
Intermittent icm will not operate - sometimes ogm won't Reel sensor won't count intermittently, thus shutting down icmtape mostly, but also sometimes the ogm. problem is during manufacturing.bracket (part no. 112) somehow was made that when ic pcb no. 906 fits intono. 112, there is space for movement between
SONY STRD2020
Major output failure - no operation Both units have the same failure shorted q-702, 703, 704,705, 706, 707, 708, 709, 710. defective ic-701, and open f-902. alsoapplies to serial number 801035. have not been able to determine whychannels are being wiped. we have noted poor and open sol
SONY CDP470
Unit reads out no disc and stops playing After playing a few discs, unit would read out no disc, cool-ing ic-4 brought back operation.
SONY TCDD3
Intermittent headphone jack Headphone connection is intermittant. i found the internalconnections had loosened from repeated insertion and removal of phones. -hq comments: i opened the unit and removed the headphone jack. iremoved the three sections of the j-303 and adjusted the
SONY RM762
After memorizing can no longer operate tv, see tvp sb # 89 Customer has a cable box which uses an infrared remotecontrol. he programs his cable box commands into the sony remote, he thenproceeds to pull up the guide menu on his tv. after getting into theguide menu, he could not access the different guide selec
SONY SPP115
Cannot put handset in test mode The procedure in the service manual on putting the handset inthe test mode does not work. -hq comments: tokyo fax (t91032). the correct procedure for putting thehandset in test mode is as follows. 1. put unit in ringer on mode.2. press talk while holdi
SONY WMD3
Intermittent output from headphones or line out Intermittent output from line out or headphone out. flexingcircuit board would show problem better.
SONY CCDF55
Defective ccd imager -- spot in picture One bad pixel in picture in the form of a white spot on theupper right hand corner of the picture. the bad imager was stamped 2j. i ordered another one and it had the same problem in the same generalarea and it was also stamped 2j. the second one i ord
SONY FH15R
Unit goes into tape function There have been (2) units which automatically revert to tapemode after a short time in any other mode.
SONY STRGX40ES
Bias adjustment procedure is incorrect Notice the bias adjust was not correct in service manual. inthe service manual it called to measure across r-710 (lf) and r-760 (rt).i believe you should measure from the emitters of q-704 and q-703 for theleft channel and from the emitters of q-754 and