SONY CDXR7
Sled intermittently will not move Intermittently the sled would not move from its innermostposition. when in the failed state the outputs q509-511 would get verywarm.
SONY KX2501A
No start up, replaced t653 Set would not start up. b + 320v, and 160v present on gaboard. troubleshooting showed only a negative going pulse to the base ofq652. also there was no pulse on the base of q651. located defectivet653.
SONY CDP302
Part number incorrect in s/m Part number listed in service manual on page 58 item 79 is4-308-840-00. this is the incorrect part number.
SONY SLHF900
Eats tape Very intermittently coming out of beta-scan, reel motor slow,but not capstan. results are tape damage since tu reel cannot wind itfast enough. -hq comments: problems of this nature are difficult to find. as wediscussed, if you send the unit to us we w
SONY CCDV8AFU
No camera video On cx23047b one pulse was missing. i think this is part ofmaster osc. giving color prob.
SONY SL2500
Part number for table assy (cap only) No part number for table assy - cap only - ref #705 (cap fort-reel table). -hq comments: this part is not available, nor is the reel table.
SONY BMC550
Missing part and part number Need p/n for four screws that fit into ref #374 on page 109.these screws are not shown in the pictorial. -hq comments: the part number for the screws is 7-685-862-09. forscrews bvtt 2.6 x 6.
SONY XR740
Wrong labelling of head pc board switches On page 41 of s/m for xr-740, 747r, 780 and 787r, thehead pc board switches are labelled incorrectly. your recent s/b #62 hasthem labelled incorrectly. the parts listing on page 41 also has themincorrectly. s701 is on page 41 of the manuals, but you h
SONY XR66
Reference number correction On page 38 of the service manual for xr-66, and on page 34 ofthe service manual for xr-80 the head pc board switches are labelledincorrectly in the parts breakout and listing below. -hq comments: we will issue a service bulletin.
SONY STRAV460
Volume changes are not linear Volume changes are erratic and jumpy when trying to changelevels with volume controls. tried changing ic601 to no avail. all otheroperations are ok. i have seen similar problems on model ta-ax520amplifiers also. this is a constant problem. -hq comme
SONY WMF1
Incorrect part number Part number listed in service manual is incorrect.
SONY WM8
Incorrect part number Part number listed for the p/b head in service manual isincorrect.
SONY STRAV560
Missing part number S/m does not list a part number for the front panel. -hq comments: part number for front panel is x-4906-723-1 for str-av560 x-4906-713-1 for str-av760
SONY EVC8U
No eject Unit would load ok. play tape for a few seconds then stop.ff or rew would run for a short time then stop. when eject was pushed thetape would unthread, but cassette compartment would not come up. the modeswitch was not running, it was staying in the l
SONY ITA500
Low volume on ogm and icm signal to telephone line Customer complains that ogm and icm volume is low and cannotbe heard if phone line quality is a little low. also, mentioned he isdissatisfied with seizing line with 1 1/2 rings. -hq comments: a modification is presently being investigated to increaseit
SONY EVS700U
Intermittently take up after pause released Item #371 on page 155 of s/m rubbing against a piece ofbad molding beneath it.
SONY D7S
Disc will not spin The unit would not spin the disc. this was caused by thethrust screw coming loose and allowing the rotor to bind. readjustmentresolved the problem. this is becoming a common problem with this unit.depending on how far out of adjustment the thrust scre
SONY CCDV8
No rf output from modulator All functions worked except there was no rf from the rfmodulator. audio and video lines worked fine.
SONY KV1944R
Snowy pix, no sound, replaced ic2006 Has snowy picture, no sound, no display. power on/off ok,could not tune channels.
SONY STRVX750
Shutdown Unit would come on for a few seconds and shut off. this wasintermittently. found with signwave input that right on out had ringingand spike on output. found r783 had changed value 39Ω. changed, sameproblem.