SONY BMC660
Microphone cover p/n There is no parts breakdown for the mike and to replace thecover only which snaps on, you have to replace the whole mike assembly.could you get us the part # for the mike -hq comments: the microphone hoods will be available shortly from kcp.the hoods ca
SONY BMC550
Microphone cover p/n There is no parts breakdown for the mike and to replace thecover only which snaps on, you have to replace the whole mike assembly.could you get us the part number for the mike? -hq comments: the microphone hoods will be available shortly from kcp.the ho
SONY CCDV8AFU
Microphone cover p/n There is no parts breakdown for the mike and to replace thecover only which snaps on, you have to replace the whole mike assembly.could you get us the part # for the mike -hq comments: the microphone hoods will be available shortly from kcp.the hoods ca
SONY CCDV8
Microphone cover p/n There is no parts breakdown for the mike and to replace thecover only which snaps on, you have to replace the whole mike assembly.could you get us the part # for the mike -hq comments: the microphone hoods will be available shortly from kcp.the hoods ca
SONY STRYX50
Missing part number Need p/n for fm front end assembly. -hq comments: part number for fe201 is a-4344-029a.
SONY XR780
Service manual errors in labelling of solenoids S/m errors in labelling of solenoids. pm701 on pg 41 ofxr-740/747r/780/787r should be pm703 (direction change solenoid). thiswould agree with their schematics and mounting diagrams. pm901 on pg 34of xr-80 and pg 38 of xr-66 should be pm903 (direction)
SONY KX2501
Shutdown, replaced h out tr insulator Set had intermittent shutdown with eventual burn out of hori-zontal output transistor.
SONY KV2690R
No pix, sound, shield on remote head amp shorting 5v line No sound or picture. low 5v line.
SONY KV20XBR
No pix, sound No pix on sound. rgb light stays on.
SONY KV25XBR
Dead set, replaced d655 Set would not come on. no output from lv supply.
SONY SPP22
Handset will not transmit Handset did not transmit. pc trace of crystal leg going tot11 broken. difficult to spot as trace had fractured where trace and landmeet.
SONY KV25XBR
Slow tuning Set was slow to tune on antenna and catv. tuning would cycleas if searching for 4 or 5 times before locking on. found loss of h syncto ic103. jumpers were omitted from pcb during production.
SONY D7S
Disc motor would not turn Disc motor would not turn. i found by removing drive belt, the motor would spin ok.
SONY SL10
Wow and flutter in sound, picture ok Wow and flutter, picture ok. removed the tension assy andlightly sanded the supply reel assy. note: this is the second unit. didthe same thing to a sl-25, see fpr. h0402.
SONY XR740
Missing p/n Part number and ref number missing: xr-740/747r/780/787r. -hq comments: item 429 should read reel retainer. item 431 should readreel assembly. we will issue s/b.
SONY SLHF500
Missing p/n's on page 120 of s/m (chassis assy 1) I need the parts located directly below ref no 184 and no 191.please inform part numbers. -hq comments: tokyo informed me these parts are not available. i didhowever locate these parts from a scrap unit in mahwah ssc. i will shipthese parts to you tod
SONY FD40A
Trapezoid effect on screen, replaced q806 Set came in with q602, d603 defective. replaced parts turnset on and 17v line was being load down to 8v causing q602 to overheat.in process of troubleshooting found waveform at junction of r871, 872distorted. checked collector of q805 also distorted.
SONY ACP80UC
Unit generates interference on tv Ac adaptor generates interference on tv sets when located ontop of set or near antenna. causes arcing on vhf chan 13 and herringboneon uhf chan 20 and 26. adding copper foil shield increased interference.three other units have same problem. -hq commen
SONY CCDM8U
Battery will not eject from compartment Battery will not eject from unit due to small plastic t shaped insert located inside compartment. apparently part is to keep battery from rattling in compartment.
SONY SL2305
No pb color There was no pb color. we found that there was no signalbeing input at ic3/p5. the signal was being lost at l6 which checkedgood with anΩmeter. however, replacement resolved the problem.