Beko Repair Tips
Search: beko
Results: 235
Results: 235
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
BEKO |
30328T
|
St/by only | No line - line dr tr t801 o/c | ||
BEKO |
30128T
|
Lop tr goes s/c | C140 22n 400v o/c | ||
BEKO |
30128T
|
Dead & ticking | Bu508df loptr s/c, c140 22n 630v o/c | ||
BEKO |
30128T
|
Dead - loptr blown & twitching/flashing when replaced | R149 surface mounted resistor should be 1k5, was up to 41k | ||
BEKO |
2841ND - 14.1 CHASSIS
|
Lines across top 3 - 4 inches of pic | R422 35v feed to ic501 fop chip never been soldered | ||
BEKO |
2832T
|
Pic takes a long time to appear | R213/4/5 22k on crt base or loptx | ||
BEKO |
28328NX
|
Nicam drop out | Reset variable cap c678 for 2.8v at pin 1 ic603 | ||
BEKO |
2812NX
|
Field scan partially missing & no tuning | R200 o/c (4r7) and ic200 tda8170 s/c | ||
BEKO |
28128NX 11.1
|
Dead aft smoke | Loptx u/s 058.541-tr1 r118 10k 0.5w in beam current sensing burnt r110 4.7r 0.5w fusible o/c in +200v supply | ||
BEKO |
28128NX
|
Dead & tripping psu | S/c bu508df loptr - when replaced int width variations - caused by wire on line dr trfmr not soldered | ||
BEKO |
28128 11.1
|
No video via scart | Tda8361 | ||
BEKO |
25411ND
|
Bright raster with sound | Pic can be restored by altering a1 or focus control - crt faulty | ||
BEKO |
20320T
|
Field collapse with rainbow effect | Replace esm740 thyristor - new type requires a 47Ω resistor from gate to power supply. | ||
BEKO |
20320NX
|
Sound pops when vol adj | Ic601 tda6610-5 | ||
BEKO |
20320NX
|
No tuning menu | Reset micro - press & hold p+/p- on set & sw on. set comes on in service mode - then sw off | ||
BEKO |
20320NX
|
Line tearing at top of pic | 220r resistor across scan coils o/c | ||
BEKO |
20320NX
|
Field scan non lin - stretched at top | 220r resistor across scan coils | ||
BEKO |
2030T
|
Rapid tuning drift | R61 27k 2w | ||
BEKO |
20306NX
|
Dead - mosfet 2sk1118 s/c | Only works short time aft replacement - chopper tfmr faulty | ||
BEKO |
20230T
|
Diagonal white/black lines across the top 6-7 inches of the frame. | 220Ω res , o/c or high res , mounted on the scan coils. |