Search: beko
Results: 235
Make Model Symptom Problem Solution By
BEKO 30328T
St/by only No line - line dr tr t801 o/c
BEKO 30128T
Lop tr goes s/c C140 22n 400v o/c
BEKO 30128T
Dead & ticking Bu508df loptr s/c, c140 22n 630v o/c
BEKO 30128T
Dead - loptr blown & twitching/flashing when replaced R149 surface mounted resistor should be 1k5, was up to 41k
BEKO 2841ND - 14.1 CHASSIS
Lines across top 3 - 4 inches of pic R422 35v feed to ic501 fop chip never been soldered
BEKO 2832T
Pic takes a long time to appear R213/4/5 22k on crt base or loptx
BEKO 28328NX
Nicam drop out Reset variable cap c678 for 2.8v at pin 1 ic603
BEKO 2812NX
Field scan partially missing & no tuning R200 o/c (4r7) and ic200 tda8170 s/c
BEKO 28128NX 11.1
Dead aft smoke Loptx u/s 058.541-tr1 r118 10k 0.5w in beam current sensing burnt r110 4.7r 0.5w fusible o/c in +200v supply
BEKO 28128NX
Dead & tripping psu S/c bu508df loptr - when replaced int width variations - caused by wire on line dr trfmr not soldered
BEKO 28128 11.1
No video via scart Tda8361
BEKO 25411ND
Bright raster with sound Pic can be restored by altering a1 or focus control - crt faulty
BEKO 20320T
Field collapse with rainbow effect Replace esm740 thyristor - new type requires a 47Ω resistor from gate to power supply.
BEKO 20320NX
Sound pops when vol adj Ic601 tda6610-5
BEKO 20320NX
No tuning menu Reset micro - press & hold p+/p- on set & sw on. set comes on in service mode - then sw off
BEKO 20320NX
Line tearing at top of pic 220r resistor across scan coils o/c
BEKO 20320NX
Field scan non lin - stretched at top 220r resistor across scan coils
BEKO 2030T
Rapid tuning drift R61 27k 2w
BEKO 20306NX
Dead - mosfet 2sk1118 s/c Only works short time aft replacement - chopper tfmr faulty
BEKO 20230T
Diagonal white/black lines across the top 6-7 inches of the frame. 220Ω res , o/c or high res , mounted on the scan coils.