Make Model Symptom Problem Solution By
CCE HPS2981
Channels going out of tune T103 Replace t103 replaced ELETRONICA MAURI JUNIOR
CCE HPS2991
Three vertically one centimeter long sparkles of brightness, one green, red and blue. at the top of the screen, with high voltage and no sound. When speeding up the screen, the screen without vertical scanning appeared, and the sound appeared. C408 (4,7mf/160), c409 (390k) c408com 0,58mf Ademir tc
CCE HPS 21AVP
Turns off after turning on C417 with leak Replace for a new one, TV is ok! #let's help, post your tip# andlss (AL TECNOLOGIA)
CCE TV-2118USP
Turns on and off sporadically, LED flashes Cold soldering on d807 Resolder this component and the others nearby. Evandro Estrela
CCE HPS2071
Dull C424 Andrade
CCE HPS 2997FS
Lacks brightness, as if the kinescope were weak, screen, filament everything ok! Abl line defect Resistor r423 1k open marcelo marques
CCE 2197FS
It takes a while for the image to appear, the screen adjustment does not give good results, it keeps blurring at the top of the screen, but at the bottom it keeps freezing, sometimes it works normally Changing the socket on the tube plate and capacitor next to it from 1k to 2k2 WISLEN
CCE HPS2991
It was without capacity, leaking and the mug didn't inflate. Replacement of capacitors c825 and c 831 It was without capacity, leaking and the mug didn't inflate. takashi murata
CCE TV 2118USP/AV
Screen slowly darkens RGB voltage goes to the limit I replaced the tr on the kinescope plate. v 923, if you don't want to waste time, replace the 3 bf 423 FERNANDO DA SÓ CONSERTOS
CCE HPS2971C/HPS2983
HPS2971
Turns on and off for 2 minutes, turns off, works well, before turning off images suffers a horizontal type of interference out of frequency, and goes into protection and turns off. Capacitor burning internally, c 406 (330 pf 2kv) connected to the horizontal output collector. ELETRÔNICA MOISES
CCE HPS21AVP
When turned on from the dark bar on the left side of the viewer, it immediately turns off. Change c417/ 330 pf, "be careful, it measured 380 pf on the capacimeter, but 6 mega of leakage" RUI
CCE HPS 2007
Three vertical lines red green blue C 301 Replace c 301 1x160 felex
CCE TV2118USP VER2.2
This TV had burned out the ic n511 cq1265rt power supply regulator So far everything was fine, I bought the component and replaced the guy but the TV didn't work and between the terminals of the zd517 the current kept oscillating, I tested and replaced almost all the components of this circuit but It didn't solve it, I had already tested c541 with the capacitance meter and it measured with a tolerance of 5 to 10 percent, so I decided to replace the 220uf/160 volt guy with a 470uf/200volt just to clear up this single doubt and then I just ran for the hug . C541 exchange for one of equal or higher value fabiusmax
CCE HPS 2007
Dark screen, with a vertical line Capacitor c 409 394j, electrolytic capacitor 4.7 x 160 v, resistor 15 k Replace of components Adenilson Boscolo
CCE TV2918USP
There are traces in the corner of the image, which increase when the TV is turned off. C402,331pf Eletronica benedito
CCE HPS 2971
Turns on the LED, turns off but does not generate an image C 409 dry and r407 altered Replace them antonionobrega(patos pb)
CCE HPS 2171 FSG
Vertical lines of linearity top Fly pacifier cable leaking, discharging in the yoke, after solving this fact, this defect arose, after testing all the components of the vertical, I decided to change the v output. Changing the vertical output, stv9325 or la 78040 (equivalent) eletronicadoalemãThis email address is being protected from spambots. You need JavaScript enabled to view it.
CCE HPS-2118C
Turning off after a few seconds, going into standby. Q804, with small leak. I replaced the q804, bc337. If not, I used the bc639, which is equivalent, and the device worked normally again. Tulio
CCE HPS3407
Width does not work (expanded screen) Inductor l405 Coil replace DEBIOUE
TVCCE TVS-2910
Sometimes when you turn on the TV, the LED goes out, but the blinking image does not appear. Check the two conds (c829- 33mf/160v, and c825- 47mf160v), abl line and its peripherals q404 and q405, but the culprit was the altered tube socket. Adilson(formiga-mg)