SONY D15
No disk spin Intermittent or constant no disk spin by clv motor. referenceno. 21 is bowed up at its narrowest point between the clv motor and thefop. check the motor for (dead spots) as it may have been damaged due tostalling.
SONY CCDF30
Cannot adjust focus ring Cannot adjust focus ring. many units have been found withvery tight focus ring (sample enclosed).
SONY SLHF300
No channel memory Intermittent loss of channel memory (-27.8v supply was low).
SONY SLV70HF
Part number correction - ic-604/mf-42 board The part number for ic-604 on the (mf-42) board (8-759-941-78)as shown in the service manual is incorrect.
SONY SLV50
Part number correction - ic-604/mf-42 board The part number for ic-604 on the (mf-42) board (8-759-941-78)as shown in the service manual is incorrect.
SONY SPP150
Intercom mode operation Customer complains the intercom does not work properly.instructions on page 19 of the instruction manual are not clear. thehandset will ring once and lock a channel for 1 or 2 seconds. whatshappening is the customer is going into the talk position afte
SONY KV25XBR
No sound or sound cracking No sound or sound cracking on some channels.
SONY KV25DXR
No color on scrambled stations on cable Problem on the exeter cable co. exeter, new hampshire(continental). the unit had no color on 1 scrambled station and flashingcolor on the other. found burst signal - measured 80mv on the stationthat was flashing and 50mv on the one with no color. all
SONY PATCH PANL
Sony patch panel Does a replacement parts list exist for the test panels usedat our sscs? in particular,dpdt center off toggle switch3pdt center off toggle switch3pdt 2-position toggle switchspecial audio sg toggle switchalso, is a similar bat handled 4pdt (center off,
SONY KV27SXR10
Vertical jump using vcr, leaky c-1734 There was a vertical jump in the picture using vcr playback.
SONY KV27TX11
No bar display, replace ic-101 No bar display on screen.
SONY CDPC20
Incorrect operation of disc drawer On power-up spindle chassis would drop and carousel wouldspin, but drawer would also open half way and then close. also, whenchanging from disc to disc, drawer would again open half way and thenclose. otherwise, unit worked correctly.
SONY D4
Incorrect voltages in service manual The voltages around ic-401, q-407 etc. in the power supplyappear incorrect. if they are incorrect, what should they be? -hq comments: pin 1 = 1.36v, 2 = .92, 3 = 1.74, 4 = 1.2, 5 = 5.72, 6 =0, 7 = 0, 8 = 9.76, 9 = 0, 10 = 3.57, 11 = 2.54, 12 = 1.28, 13
SONY KPR4620
Dust on screen, replaced screen Dust on screen.
SONY EDC55
Lens hood, lens cap and grip belt part numbers The part numbers for the lens hood, lens cap and grip belt areas follows: description part number lens hood 3-730-741-01 lens cap 3-730-742-01 grip belt 3-730-743-01 -hq comments: a
SONY FD35
Tuning dial for fd-35a Detroit ssc has received four cabinet assemblies (front) andthe tuner dial is missing. there is no part number for dial so i assumethis should be part of the cabinet. could you please check into this?thanks. -hq comments: tuning indicator is included
SONY CDXA10
Cnp901 line out cable Cannot identify part number for cable between jack board andmain board. two versions - older units (serial no. 17627) have a single8-pin connector for the jack board and dual 3-pin (5-pin connectors) forthe main board. newer units (serial no. 22395) ha
SONY CCDF30
No color e-e in camera mode No color from camera section and line in. all other functionsworked properly. found q-360 not switching properly. it would not toggleic-365 on ic-364. camera 5v out of dc-dc converter was just low enough tokeep q-362 on about 3.7vdc. this in turn wo
SONY CCDV3
No camera luminance No luminance coming from camera section. pin 36 of ic-801had no luminance signal, all dc voltages were correct and all signals toic-801 were present - yh, b-y, r-4 and yl-yh. changed ic-801 still noluminance.
SONY KV27SXR10
Line across top of screen, ag holder, no solution The outside tech in costa mesa informed me of customerscomplaining about the three band that hold the aperture grille fromoscillating. the problem is the customer can see the top line from adistance of 7 to 8 feet. the tech has been out to four custome